T-120D Mean Well, T-120D Datasheet

Linear & Switching Power Supplies 118W 5V/8A

T-120D

Manufacturer Part Number
T-120D
Description
Linear & Switching Power Supplies 118W 5V/8A
Manufacturer
Mean Well
Datasheet

Specifications of T-120D

Product
Switching
Commercial/medical
Commercial
Output Power Rating
40 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
8 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
24 V
Output Current (channel 3)
2 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
120W Triple Output Switching Power Supply
Note.3
Note.2
T-120A
CH1
5V
11A
2 ~ 12A
120W
80mVp-p 120mVp-p 80mVp-p
CH1: 4.75 ~ 5.5V
800ms, 20ms/230VAC
24ms/230VAC
88 ~ 132VAC/176 ~ 264VAC selected by switch
47 ~ 63Hz
2.2A/115VAC
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, CCC GB4943 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to
274.5K hrs min.
199*110*50mm (L*W*H)
0.83Kg; 16pcs/14.2Kg/0.95CUFT
77%
COLD START 32A
<3.5mA / 240VAC
2.0%
0.5%
0.5%
0.03%/
CH2
12V
5A
0.5 ~ 5A 0.2 ~ 1A
(0~50 )
6.0%
1.0%
5.0%
(Refer to output load derating curve)
EN61000-4-2,3,4,5,6,8,11; ENV50204,
I/P-FG:1.5KVAC
1.3A/230VAC
MIL-HDBK-217F (25 )
14ms/115VAC at full load
CH3
-5V
1A
6.0%
1.0%
5.0%
1600ms, 20ms/115VAC at full load
T-120B
CH1
5V
11A
2 ~ 12A
121W
80mVp-p
77%
2.0%
0.5%
0.5%
O/P-FG:0.5KVAC
CH2
12V
4.5A
0.5 ~ 5A 0.2 ~ 1A
120mVp-p 120mVp-p
6.0%
1.0%
5.0%
240 ~ 370VDC
EN55024, light industry level, criteria A
CH3
-12V
1A
6.0%
1.0%
5.0%
T-120C
CH1
5V
10A
2 ~ 12A
117.5W
80mVp-p
76%
2.0%
0.5%
0.5%
CH2
15V
3.5A
0.5 ~ 5A 0.2 ~ 1A
150mVp-p 150mVp-p
+10,-5%
1.0%
6.0%
CH3
-15V
1A
+10,-5%
1.0%
6.0%
T- 1 2 0
T-120D
CH1
5V
8A
2 ~ 12A
118W
80mVp-p
80%
2.0%
0.5%
0.5%
File Name:T-120-SPEC 2010-10-18
CH2
12V
2.5A
0.2 ~ 5A 0.2 ~ 2A
120mVp-p 180mVp-p
6.0%
1.0%
5.0%
s e r i e s
CH3
24V
2A
6.0%
1.0%
5.0%

Related parts for T-120D

T-120D Summary of contents

Page 1

... I/P-FG:1.5KVAC O/P-FG:0.5KVAC EN61000-4-2,3,4,5,6,8,11; ENV50204, MIL-HDBK-217F ( T-120C T-120D CH3 CH1 CH2 CH3 CH1 -12V 5V 15V -15V 5V 1A 10A 3. 12A 0 0 12A 117 ...

Page 2

... INPUT VOLTAGE (V) 60Hz File Name:T-120-SPEC 2010-10- Unit:mm Assignment DC OUTPUT DC OUTPUT COM DC OUTPUT +5V T-120D +24V +12V NC fosc : 25KHz Ta=25 300 12V 250 +5V 200 150 100 +12V 50 25 +5V 125 130 250 ...