MCP2140-I/P Microchip Technology, MCP2140-I/P Datasheet - Page 14

IC IRDA CONTROLLER DTE/DCE 18DIP

MCP2140-I/P

Manufacturer Part Number
MCP2140-I/P
Description
IC IRDA CONTROLLER DTE/DCE 18DIP
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP2140-I/P

Package / Case
18-DIP (0.300", 7.62mm)
Controller Type
IRDA Standard Protocol Stack Controller
Interface
UART
Voltage - Supply
3 V ~ 5.5 V
Current - Supply
2.2mA
Operating Temperature
-40°C ~ 125°C
Mounting Type
Through Hole
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
MCP2140DM-TMPSNS - BOARD DEMO FOR MCP2140
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP2140-I/P
Manufacturer:
Microchip
Quantity:
28
Part Number:
MCP2140-I/P
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
MCP2140
2.8
During IR communication between a Primary Device
and the MCP2140, the MCP2140 is in an operational
mode. In this mode, the MCP2140 consumes the
operational current
For many applications, the time that IR communication
is occurring is a small percentage of the applications
operational time. The ability for the IR controller to be
in a low power mode during this time will save on the
applications power consumption. The MCP2140 will
automatically enter a low power mode once IR activity
has stopped and will return to operational mode once
IR activity is detected on the RXPD and RXPDREF
pins.
Another way to minimize system power is to use an I/O
pin of the Host Controller to enable power to the IR
circuity
DS21790A-page 14
Minimizing Power
(Parameter
D010).
Preliminary
2.8.1
The Automatic Low Power mode allows the system to
achieve the lowest possible operating current.
When the IR link has been “closed”, the protocol han-
dler state machine returns to the Normal Disconnect
Mode (NDM). During NDM, if no IR activity occurs for
about 10 seconds, the device is disabled and enters
into Low Power mode. In this mode, the device oscilla-
tor is shut down and the PHACT pin will be low
(Parameter
Table 2-3
specified in
TABLE 2-3:
2.8.2
The device will exit the Low Power mode when the
RXPD pin voltage crosses the REPDREF pin reference
voltage.
A device reset will also cause the MCP2140 to exit Low
Power mode. After device initialization, if no IR activity
occurs for about 10 seconds, the device is disabled and
returns into the Low Power mode.
2.9
The PHACT signal indicates that the MCP2140 Proto-
col Handler is active. This output pin is an open collec-
tor, so when interfacing to the Host Controller, a pull-up
resistor is required.
PHACT = H
PHACT = L
Note:
Note:
Mode
PHACT Signal
shows the MCP2140 current. These are
Additional system current is from the
Receiver/Transmitter circuitry.
For proper operation, the device oscillator
must be within oscillator specification in
the
Parameter
AUTOMATIC LOW POWER MODE
RETURNING TO DEVICE
OPERATION
D010A).
Parameter D010
Current
2.2 mA
60 µA
DEVICE MAXIMUM
OPERATING CURRENT
time
IR140.
IR communications is
occurring.
No IR communications.
2003 Microchip Technology Inc.
frame
and
Parameter
Comment
specified
D010A.
in

Related parts for MCP2140-I/P