EMC1428-1-AP-TR SMSC, EMC1428-1-AP-TR Datasheet - Page 30

no-image

EMC1428-1-AP-TR

Manufacturer Part Number
EMC1428-1-AP-TR
Description
Board Mount Temperature Sensors Octal Temp Sensor
Manufacturer
SMSC
Datasheet

Specifications of EMC1428-1-AP-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
ADDR
03h
09h
Revision 0.69 (06-29-09)
5.4
5.5
ADDR
0Ah
04h
R/W
R/W
Configuration Register
Conversion Rate Register
REGISTER
Bit 2 - FAULT - This bit is asserted when a diode fault is detected on any of the external diode
channels. See the External Diode Fault Register for specific channel information
set, this bit will assert the ALERT pin.
Bit 1 - SW_SYS - This bit is set when any of the external diode channels meet or exceed the respected
THERM Limits. See the Therm Status Register for specific channel information
Bit 0 - HWSD - This bit is set when the External Diode 1 Temperature meets or exceeds the Hardware
Critical / Thermal Shutdown Limit. When set, this bit will assert the SYS_SHDN pin. This bit is cleared
when read if the SYS_SHDN pin has been released.
The Configuration Register controls the basic operation of the device. This register is fully accessible
at either address.
Bit 7 - MASK_ALL - Masks the ALERT pin from asserting.
Bit 5 - ALERT/COMP - Controls the operation of the ALERT pin.
Bit 1 - DAVG_DIS - Disables the dynamic averaging feature on all temperature channels (see
Section
Config
R/W
R/W
‘0’ (default) - The ALERT pin is not masked. If any of the appropriate status bits are set the ALERT
pin will be asserted.
‘1’ - The ALERT pin is masked. It will not be asserted for any interrupt condition. The Status
Registers will be updated normally.
‘0’ (default) - The ALERT pin acts as described in
‘1’ - The ALERT pin acts in comparator mode as described in
MASK_ALL bit is ignored.
‘0’ (default) - The dynamic averaging feature is enabled. All temperature channels will be converted
with an averaging factor that is based on the conversion rate as shown in
‘1’ - The dynamic averaging feature is disabled. All temperature channels will be converted with a
maximum averaging factor of 1x (equivalent to 11-bit conversion). For higher conversion rates (i.e.
more conversions per second), this averaging factor will be reduced as shown in
4.5.6).
MASK_
REGISTER
Conversion
ALL
B7
Rate
Table 5.6 Conversion Rate Register
B6
Table 5.5 Configuration Register
-
B7
1°C Multiple Temperature Sensor with HW Thermal Shutdown & Hottest of Thermal Zones
-
DATASHEET
ALERT/
COMP
B5
B6
-
30
B4
B5
-
-
Section
B4
-
B3
-
B3
4.1.1.
Section
B2
-
B2
CONV[2:0]
4.1.2. In this mode the
B1
DAVG_
DIS
B1
Table
(Section
(Section
B0
4.2.
Table
SMSC EMC1428
B0
5.20)
-
DEFAULT
5.9). When
4.2.
(4/sec)
Datasheet
06h
DEFAULT
00h

Related parts for EMC1428-1-AP-TR