MAX1989MUE Maxim Integrated Products, MAX1989MUE Datasheet - Page 15

no-image

MAX1989MUE

Manufacturer Part Number
MAX1989MUE
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1989MUE

Full Temp Accuracy
+/- 3.5 C, +/- 5 C
Package / Case
TSSOP-16
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
7 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1989MUE
Manufacturer:
MAXIM
Quantity:
6
Part Number:
MAX1989MUE
Manufacturer:
SIPEX
Quantity:
1
Company:
Part Number:
MAX1989MUE
Quantity:
105
Figure 4. SMBus Read Timing Diagram
Figure 5. SMBus Write Timing Diagram
Table 8. Slave Address Decoding (ADD0
and ADD1)
Note: High-Z means that the pin is left unconnected and floating.
SMBCLK
SMBDATA
SMBCLK
SMBDATA
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
High-Z
High-Z
High-Z
ADD0
GND
GND
GND
V
V
V
CC
CC
CC
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
t
SU:STA
t
SU:STA
A
A
t
HD:STA
t
HD:STA
______________________________________________________________________________________
t
LOW
t
LOW
High-Z
High-Z
High-Z
ADD1
GND
GND
GND
V
V
V
B
B
CC
CC
CC
t
HIGH
t
HIGH
t
t
SU:DAT
SU:DAT
C
C
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
ADDRESS
0011 000
0011 001
0011 010
0101 001
0101 010
0101 011
1001 100
1001 101
1001 110
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
D
D
Multichannel Remote/Local
E
E
F
F
t
HD:DAT
Temperature Sensors
G
G
H
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION
H
I
J
I
K
t
SU:STO
t
SU:STO
J
t
L
BUF
t
BUF
K
M
15