MAX6658MSA Maxim Integrated Products, MAX6658MSA Datasheet - Page 10

no-image

MAX6658MSA

Manufacturer Part Number
MAX6658MSA
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6658MSA

Full Temp Accuracy
+/- 5 C
Package / Case
SOIC-8 Narrow
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX6658MSA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX6658MSA+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX6658MSA+T
Manufacturer:
MAXIM
Quantity:
39
Part Number:
MAX6658MSA+T
0
±1°C, SMBus-Compatible Remote/Local Temperature
Sensors with Overtemperature Alarms
2) If the MAX6657/MAX6658/MAX6659 are in run mode,
10
Figure 4. SMBus Read Timing Diagram
Figure 3. SMBus Write Timing Diagram
1. Initiate a one-shot conversion using Command
Byte 0Fh. When this conversion is complete, read
the contents of the Temperature Data registers.
read the Status register. If a conversion is in
progress, the BUSY bit is set to 1. Wait for the con-
version to complete as indicated by the BUSY bit
being set to 0, then read the Temperature Data reg-
isters. Note that the power-on reset sets the conver-
sion rate to 16Hz, so no extended data is valid
without reducing the conversion rate to 4Hz or less.
______________________________________________________________________________________
SMBCLK
SMBDATA
SMBCLK
SMBDATA
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
t
t
SU:STA
SU:STA
A
A
t
t
HD:STA
HD:STA
t
t
LOW
LOW
B
B
t
t
HIGH
HIGH
t
t
SU:DAT
SU:DAT
C
C
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = MASTER PULLS DATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
D
D
E
E
F
F
There is a continuity fault detector at DXP that detects
an open circuit between DXP and DXN, or a DXP short
to V
the external temperature register is loaded with 1000
0000. Additionally, if the fault is an open circuit, bit 2
(OPEN) of the status byte is set to 1 and the ALERT con-
dition is activated at the end of the conversion.
Immediately after POR, the Status register indicates that
no fault is present until the end of the first conversion.
t
t
HD:DAT
HD:DAT
CC
, GND, or DXN. If an open or short circuit exists,
G
G
H
H
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
I
I
J
J
K
K
Diode Fault Alarm
t
t
SU:STO
SU:STO
L
L
t
t
BUF
BUF
M
M

Related parts for MAX6658MSA