E2C-C1A Omron, E2C-C1A Datasheet

no-image

E2C-C1A

Manufacturer Part Number
E2C-C1A
Description
Proximity Sensors SEP.AMP.PROX 5.4MM 2mm DIST
Manufacturer
Omron
Series
E2Cr
Datasheets

Specifications of E2C-C1A

Maximum Operating Temperature
+ 70 C
Sensing Distance
1 mm
Minimum Operating Temperature
- 25 C
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
1kHz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
-
Output Type
-
Terminal Type
2-Wire
Package / Case
Cylinder
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Plug-in Sensor Amplifiers with Direct
CompoBus/S Terminal Connections
1
1
1
Ordering Information
3 COMPOBUS/S SENSOR AMPLIFIER TERMINALS
3 SENSOR AMPLIFIERS
The amplifiers and terminal block below do not include the required sensing head. Order those separately from the partial listing below.
For detailed sensor performance specifications and a complete product offering, request a Sensing Products catalog or visit our web site
at www.omron.com/oei .
Communications
Expansion
Fiber-optic sensor
amplifiers for Omron’s
E32-series fiber-optic
E32-series fiber-optic
cables
Inductive proximity sensor
amplifier
Terminal block
Remote Sensor Amplifier Terminal
SRT1 models support only high-speed
communications systems
4-point terminals expand to 8 points
max. with optional expansion terminal
Easily mounts to DIN rail track or with
screws for panel mounting
Classification
lifi
Classification
f
O
E3X-NTP6, E39-JID01 or E2C-T16 amplifiers
E3X-NM16 amplifier
E3X-NTP6, E39-JID01 or E2C-T16 amplifiers
E3X-NM16 amplifier
General-purpose amplifier, 1 channel
Multi-functional amplifier, 1 channel, with OFF-delay timer and teach function
Long distance, high accuracy amplifier, 1 channel, 3 teach modes, scaled
sensitivity and threshold displays
Multi-functional amplifier, 4 channels, with OFF-delay timer and teach function
Sensor detects all metal targets, offers teach function, 1 channel; use E2C
sensing heads
Connect any 2-wire or 3-wire DC photoelectric or proximity sensor, limit switch
or basic switch; 1 channel
Applicable sensor amplifier models
9
Specifications
4 single-point amplifiers
1 four-point amplifier
4 single-point amplifiers
1 four-point amplifier
I/O points
SRT1-P P P P P P P P D04S
SRT1-TID04S
SRT1-TKD04S
SRT1-XID04S
SRT1-XKD04S
E3X-NT16
E3X-NT26
E3X-NH16
E3X-NM16
E2C-T16
E39-JID01
Part number
Part number

Related parts for E2C-C1A

E2C-C1A Summary of contents

Page 1

... Multi-functional amplifier, 4 channels, with OFF-delay timer and teach function Inductive proximity sensor Sensor detects all metal targets, offers teach function, 1 channel; use E2C amplifier sensing heads Terminal block Connect any 2-wire or 3-wire DC photoelectric or proximity sensor, limit switch or basic switch ...

Page 2

... Sensor Amplifiers or Terminal Block Inductive Proximity amplifier (1 channel) SRT1 D04S Part number E32-TC200 E32-T17L E32-T61 E32-DC200 E32-D61 E2C-CR5B2 E2C-CR8A E2C-X1A E2C-C1A E2C-X1R5A Terminal Block Unit (1 channel) Various sensor and switch types can be connected. Photoelectric sensor Basic switch and limit switch Proximity sensor ...

Page 3

... Operating: 35% to 85% Weight 70 g max. Note: 1. The communications power supply voltage must be 20.4 to 26.4 VDC if the Terminal is connected to 2-wired proximity sensors. 2. When adding Amplifier Terminals, use SRT1-XID04S or SRT1-XKD04S. 3. The value doesn’t include the current consumption of Amplifier Terminals. E3X- Fiber-optic Amplifiers ...

Page 4

... Orange LED: Lit during output operation Green LED: Lit with stable signal input Temperature influence 25% max. of sensing distance for E2C-CR5B2 10% max. of sensing distance for E2C-CR5B2, E2C-CR8A, E2C-X1A, E2C-C1A Differential travel 15% max of sensing distance for E2C-CR5B2 10% max. of sensing distance for E2C-CR5B2, E2C-CR8A, E2C-X1A, E2C-C1A ...

Page 5

SRT1 D04S Nomenclature SRT1-TID04S SRT1-TKD04S Communications Terminals Communications Terminals Connect a commu- nications cable. Indicators Indicators Indicator Name Display PWR Power supply y Lit Not lit COMM Communications Lit Not lit ERR Communications ...

Page 6

SRT1 D04S Node Number Settings Node number 1 0 OFF OFF OFF OFF OFF OFF ...

Page 7

SRT1 D04S SRT1-XID04S SRT1-TKD04S Two, 4.5 dia. 17 4.5 41.2 (1.62) 41 (1.61) Two, 4.5 dia (2.05 (1.61) SRT1 ...

Page 8

SRT1 D04S Unit: mm (inch) SRT1-XKD04S E3X-NM16 32.2 (1.27 Two, 4.5 dia. 17 4.5 33 (1.30) 41 (1.61) Output indicator 7 8.3 7 10.8 Eight, 2.4 dia. 33 ...

Page 9

SRT1 D04S E3X-NH16 E3X-NTP6 Threshold indicators Output indicator 10 (0.39) Two, 2.4 dia. 8 10.7 13 Output indicator 10 (0.39) Two, 2.4 dia. 8 10.7 13 SRT1 ...

Page 10

... SRT1 D04S Unit: mm (inch) E2C-T16 10 (0.39) 4 (0.16) 2 (0.08) R2 21.8 (0.86) E39-JID01 Installation 3 INTERNAL CIRCUIT CONFIGURATION E39-JID01 Internal circuit 10 OUT indicator STB indicator 0.5 (0.02) 22.6 2 (0.89) (0.08) 70 (2.76) 32.5 (1.28) 24 36.7 (0.94) (1.44) Output indicator 10.9 59 (2.32) 6.1 10.5 64.5 (2.54) ...

Page 11

SRT1 D04S Precautions Refer to the CompoBus/S Operation Manual (W266) before using the Terminal. 3 GENERAL SAFETY PRECAUTIONS Sensor Amplifiers Use only the Sensor Amplifier models listed in this data sheet with the ...

Page 12

... CompoBus/S terminal. Bottom View Section A Section C Section A Section B NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RIO-1 04/00 Removing 4-Channel Amplifiers 1. While pushing Section D, pull the Amplifier in direction E. ...

Related keywords