E2C-EDA11 2M Omron, E2C-EDA11 2M Datasheet - Page 6

Proximity Sensors Smart Prox Sensor

E2C-EDA11 2M

Manufacturer Part Number
E2C-EDA11 2M
Description
Proximity Sensors Smart Prox Sensor
Manufacturer
Omron
Datasheet

Specifications of E2C-EDA11 2M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Amplifier Units
* Communications are disabled if the super-high-speed sensing mode is selected, and the mutual interference prevention function and the communications functions
Item
Power supply voltage
Power consumption
Control output
Re-
sponse
time
Func-
tions
Digital display
Display orientation
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
for the Mobile Console will not function.
Model NPN output
Super-high-
speed mode
High-speed
mode
Standard
mode
High-resolu-
tion mode
Differential
detection
Timer
Zero-reset
Initial reset
Mutual
interference
prevention
Hysteresis
setting
I/O settings
Case
Cover
PNP output
Model
*
12 to 24 VDC ± 10%, ripple (p-p): 10% max.
1,080 mW max. (Current consumption: 45 mA at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC max., Open-collector output (NPN or PNP depending on model), Load current:
50 mA max. (Residual voltage: 1 V max.)
Operate or reset: 150 µ s max.
Operate or reset: 300 µ s max.
Operate or reset: 1 ms max.
Operate or reset: 4 ms max.
Switchable between single edge and double edge detection mode.
Single edge: Can be set to 300 µ s, 500 µ s, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 µ s, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1 s-increments)
Negative values can be displayed. (Threshold is not shifted.)
Settings can be returned to defaults as required.
Possible for up to 5
Setting range: 10 to 4,000
Output setting (Select from channel 2 output, area output,
self-diagnosis, or open circuit detection.)
Select from the following: Incident level + threshold, incident level percentage +threshold, incident light peak level +
incident light bottom level (updated with output), long bar display, incident level + peak hold, incident level + channel
Switching between normal/reversed display is possible.
Operating: When connecting 1 to 2 Units: − 10 ° C to 55 ° C, When connecting 3 to 5 Units: − 10 ° C to 50 ° C, When con-
necting 6 to 16 Units: − 10 ° C to 45 ° C
When used in combination with an EDR6-F
When connecting 3 to 4 Units: − 10 ° C to 50 ° C, When connecting 5 to 8 Units: − 10 ° C to 45 ° C, When connecting 9 to
16 Units: − 10 ° C to 40 ° C
Storage: − 20 to 70 ° C (with no icing)
Operating/storage: 35% to 85% (with no condensation)
20 M Ω min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP50
Pre-wired Models
Approx. 100 g
PBT
Polycarbonate
E2C-EDA11
E2C-EDA41
Advanced Models with Twin Outputs
Units.*
2
3 times each in X, Y, and Z directions
Intermittent oscillation method (Response time = (number of Units connected + 1) × 15 ms)
Connector Models
Approx. 55 g
E2C-EDA6
E2C-EDA8
Input setting (Select from teaching, fine positioning, zero-
reset, synchronous detection.)
Pre-wired Models
Approx. 100 g
E2C-EDA21
E2C-EDA51
Advanced Models with External Inputs
Connector Models
Approx. 55 g
E2C-EDA7
E2C-EDA9
E2C-EDA
Proximity
Sensors
Sensing
Guide
Cylindrical
Models
Rectangular
Models
Separate Amp/
Pre-wired
Connector
Models
Capacitive
Models
Others
Peripheral
Devices
General
Information
853
E2EC
E2C-EDA
E2C-EDA
E2C
/E2C-H
E2CY

Related parts for E2C-EDA11 2M