E2K-C25ME1-5M Omron, E2K-C25ME1-5M Datasheet - Page 3

Proximity Sensors E2K C25ME1 W/ 5 METE R CABLE

E2K-C25ME1-5M

Manufacturer Part Number
E2K-C25ME1-5M
Description
Proximity Sensors E2K C25ME1 W/ 5 METE R CABLE
Manufacturer
Omron
Series
E2K-Cr
Type
Proximity Sensorr
Datasheets

Specifications of E2K-C25ME1-5M

Maximum Operating Temperature
70 C
Supply Voltage
12 VDC to 24 VDC
Supply Current
15 mA
Output Voltage
2 V
Operating Supply Voltage
10 VDC to 40 VDC
Mounting Style
Bracket
Sensing Distance
3 mm to 25 mm
Minimum Operating Temperature
- 25 C
Current Rating
200 mA
Features
Permits non-contact detection of metallic and non-metallic objects, mounting bracket included
Voltage Rating
24 VDC
Sensor Type
Capacitive
Sensing Object
Metallic and Non-Metallic
Response Frequency
70Hz
Material - Body
ABS/PC
Shielding
Unshielded
Voltage - Supply
10 V ~ 40 V
Output Type
NPN-NO
Terminal Type
3-Wire
Package / Case
Cylinder
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Noise-resistant Models
*1. The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data on page 4 for other materials.
*2. The response frequency is an average value.
*3. Only 2-m cables are available. Use a cable with a conductor cross section of 0.5 mm
Item
Sensing distance
*1
Sensing area
Detectable object Conductors and dielectrics
Standard
sensing object
Differential travel 15% max. of sensing distance (when adjusted to 20 mm ±10% with standard sensing object)
Response
frequency *2
Power supply
voltage
(operating
voltage range)
Current
consumption
Leakage current
Con-
trol
out-
put
Indicators
Operation mode
(with sensing ob-
ject approach-
ing)
Protection
circuits
Ambient temper-
ature range
Ambient
humidity range
Temperature
influence
Voltage influence ±2% max. of sensing distance at the rated voltage in rated voltage ±15% range
Insulation
resistance
Dielectric
strength
Vibration
resistance
Shock resistance Destruction: 500 m/s
Degree of
protection
Connection
method *3
Weight
(packed state)
Mate-
rials
Accessories
Load
current
Residual
voltage
Case
Sensing
surface
Model
20 mm
3 to 20 mm
Grounded metal plate: 50 × 50 × 1 mm
40 Hz
12 to 24 VDC (10 to 36 VDC), ripple (p-p): 10% max.
13 mA max. at 24 VDC
250 mA max.
2.5 V max. (Load current: 250 mA, Cable length: 2 m)
Operation indicator (yellow)
C1/T1 Models: NO
C2/T2 Models: NC
Reverse polarity protection, Load short-circuit protection
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −10 to 55°C
±25% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 min between current-carrying
parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
IEC 60529 IP65
Pre-wired Models (Standard cable length: 2 m)
Approx. 240 g
PBT
Mounting Bracket, Instruction manual
E2K-C20MC1
Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.
2
10 times each in X, Y, and Z directions
---
E2K-C20MC2
2
or greater to extend the cable.
AC power: 25 Hz, DC power: 40 Hz
24 to 240 VAC (20 to 250 VAC), 50/60 Hz; 24 to 240 VDC (20
to 250 VDC)
1.5 mA max. at 24 VDC, 1.7 mA max. at 110 VAC (50/60 Hz),
2.5 mA max. at 250 VAC (50/60 Hz)
Refer to Engineering Data on page 4.
5 to 200 mA (resistive load)
AC power: 10 V max., DC power: 8 V max.
Refer to Engineering Data on page 4.
1,500 VAC, 50/60 Hz for 1 min between current-carrying
parts and case
E2K-C20MT1
---
---
E2K-C20MT2
E2K-C
3