E2E-X5Y1 Omron, E2E-X5Y1 Datasheet - Page 16

Proximity Sensors PROXIMITY SWITCH

E2E-X5Y1

Manufacturer Part Number
E2E-X5Y1
Description
Proximity Sensors PROXIMITY SWITCH
Manufacturer
Omron
Series
E2Er
Datasheets

Specifications of E2E-X5Y1

Maximum Operating Temperature
+ 85 C
Supply Voltage
24 V
Operating Supply Voltage
24 VAC to 240 VAC
Mounting Style
Panel
Sensing Distance
5 mm
Minimum Operating Temperature
- 40 C
Maximum Output Current
300 mA
Features
High visibility indicator
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
25Hz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
20 VAC ~ 264 VAC
Output Type
SCR-NO
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M18
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E2E-X5Y1-Z
Manufacturer:
OMRON
Quantity:
463
J PRECAUTIONS FOR AC 2-WIRE PROXIMITY SENSORS IN OPERATION, CONTINUED
Cat. No. CEDSAX4
Model
AC
2-wire
E2E 2-WIRE AC
1-800-55-OMRON
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
Connection type
OR
(parallel connection)
R
11/01
Method
A
A
B
B
OMRON ON- -LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
Specifications subject to change without notice.
Incorrect
Correct
Load
Load
VAC power
supply V
S
Description
In principle, more than two Proximity Sensors
cannot be connected in parallel.
Provided that Proximity Sensor A does not
operate with Proximity Sensor B simultaneously
and there is no need to keep the load operating
continuously, the Proximity Sensors can be
connected in parallel. In this case, however, due
to the total leakage current of the Proximity
Sensors, the load may not reset properly.
It is not possible to keep the load operating
continuously with Proximity Sensors A and B in
simultaneous operation to sense sensing objects
due to the following reason.
When Proximity Sensor A is ON, the voltage
imposed on Proximity Sensor A will drop to
approximately 10 V and the load current flows
into Proximity Sensor A, and when one of the
sensing objects is close to Proximity Sensor B,
Proximity Sensor B will not operate because the
voltage imposed on Proximity Sensor B is 10 V,
which is too low. When Proximity Sensor A is
OFF, the voltage imposed on Proximity Sensor B
will reach the supply voltage and Proximity
Sensor B will be ON. Then, Proximity Sensor A
as well as Proximity Sensor B will be OFF for
approximately 10 ms, which resets the load for
an instant. To prevent the instantaneous
resetting of the load, use a relay as shown on the
left.
OMRON CANADA, INC.
416-286-6465
885 Milner Avenue
Scarborough, Ontario M1B 5V8
E2E 2-WIRE AC
Printed in U.S.A.

Related parts for E2E-X5Y1