19U015PV1L Honeywell, 19U015PV1L Datasheet

no-image

19U015PV1L

Manufacturer Part Number
19U015PV1L
Description
Industrial Pressure Sensors JZ STAINLESS PRESS
Manufacturer
Honeywell
Type
Vacuum Gager
Datasheet

Specifications of 19U015PV1L

Operating Pressure
0 psi to 15 psi
Pressure Type
Vacuum, Gauge, Differential
Output Type
Basic
Mounting Style
Panel
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
2 mA
Pressure Port
N
Sensor Type
Transducers
Pressure Range
0 to 15Psi
Overload Pressure (max)
45Psi
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (max)
15V
Lead Free Status / Rohs Status
Compliant
Pressure Sensors
Low-Cost, Stainless Steel, Isolated Sensors
FEATURES
• Low cost
• Rugged, isolated stainless
• Small size
• Reliable semiconductor
• Calibrated and
• Absolute and gage
• Vacuum compatible,
• 0 psi to 3 psi to, 0 psi to
TYPICAL APPLICATIONS
• Industrial controls
• Process control systems
• Industrial automation and
• Pressure calibrators
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
steel package
technology
temperature compensated
pressures
isolated sensors
500 psi
flow control
WARNING
sensors were developed for pressure applications that involve measurement
of hostile media in harsh environments compatible with 316 stainless steel.
The special Vacuum Gage Series sensors are specifically designed for
applications that can be exposed to vacuum.
available for use with either a constant voltage or current source. They
feature a variety of pressure connections to allow use in a wide range of
OEM (Original Equipment Manufacturer) equipment. The 19U Series is
uncompensated for applications that use their own specialized circuit
designs.
use in a wide variety of pressure sensing applications where corrosive
liquids or gases are monitored.
19C, 19U, AND 19 VACUUM GAGE EQUIVALENT CIRCUIT
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
• Complete installation, operation, and maintenance information is provided
Failure to comply with these instructions could result in death or
serious injury.
Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage Series
The 19C Series are calibrated and temperature compensated. They are
The 19C and 19U Series sensors are rugged and reliable transducers for
not use this document as a product installation guide.
in the instructions supplied with each product.
WARNING
19 mm Series

Related parts for 19U015PV1L

19U015PV1L Summary of contents

Page 1

... Failure to comply with these instructions could result in death or serious injury. Sensing and Control Honeywell’s stainless steel 19C, 19U, and 19 Vacuum Gage Series The 19C Series are calibrated and temperature compensated. They are The 19C and 19U Series sensors are rugged and reliable transducers for WARNING not use this document as a product installation guide ...

Page 2

... Common mode voltage (voltage version “K”) Input impedance (current version “L”) Input impedance (voltage version “K”) Output resistance 2 Honeywell • Sensing and Control 0 ° °C [32 °F to 180 °F] -40 °C to 125 °C [-40 °F to 257 °F] -40 °C to 125 °C [-40 °F to 257 °F] ...

Page 3

... Temp. coefficient of span (0 ° °C [32 °F to 180 °F]) Thermal hysteresis (0 ° °C [32 °F to 180 °F]) (5) Long-term stability of offset and span (6) Response time Input resistance Output resistance Honeywell • Sensing and Control (1) Minimum Typical -7.5 1 – ±0.1 – ...