SPT4V3000PA4W02 Honeywell, SPT4V3000PA4W02 Datasheet - Page 3

no-image

SPT4V3000PA4W02

Manufacturer Part Number
SPT4V3000PA4W02
Description
Industrial Pressure Sensors JZ STAINLESS PRESS
Manufacturer
Honeywell
Type
Absoluter
Datasheet

Specifications of SPT4V3000PA4W02

Operating Pressure
0 psi to 3000 psi
Pressure Type
Absolute
Mounting Style
Stud
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
10 V to 24 V
Supply Current
5 mA
Output Voltage
4 V
Port Size
1/8 in - 27 NPT
Pressure Port
Y
Sensor Type
Transducers
Pressure Range
0 to 3000Psi
Overload Pressure (max)
9000Psi
Mounting
Stud
Pin Count
4
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Operating Supply Voltage (typ)
12/15/18V
Operating Supply Voltage (min)
10V
Operating Supply Voltage (max)
24V
Lead Free Status / Rohs Status
Not Compliant
Table 3. Performance Specifications
Notes:
1. Reference conditions (unless otherwise noted): T
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale positive pressure and the output at zero pressure. FSS
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the maximum output difference
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F] reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10% to 90% rise time.
7. Common mode voltage as measure from output to ground.
Characteristic
SPT mV Version
Zero pressure offset
Full-scale span (0 psig to 3 psig and 0 psig-5 psig only)
Full-scale span (0 psi to10 psi and 0 psi to 3000 psi only)
Full-scale span (0 psi to 5000 psi only)
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. effect on span
Temp. effect on offset
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only)
Thermal hysteresis (-10 °C to 85 °C [14 °F to 185 °F])
Long-term stability of offset and span
Response time
Common mode voltage (voltage version “K”)
Input resistance
Output resistance
SPT mA Version
Zero pressure offset
Full-scale span
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. effect on span
Temp. effect on offset
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only)
Thermal hysteresis -10 °C to 85 °C [14 °F to 185 °F]
Long term stability of offset and span
Response time
SPT 4V Version
Zero pressure offset
Full-scale span
Pressure non-linearity
Pressure hysteresis
Repeatability
Temp. effect on span
Temp. effect on offset
Temp. effect on span (0 psi to 3 psi and 0 psi to 5 psi only)
Temp. effect on offset (0 psi to 3 psi and 0 psi to 5 psi only)
Thermal hysteresis -10 °C to 85 °C [14 °F to 185 °F]
Long term stability of offset and span
Response time
V
is ratiometric to the supply voltage.
at any point within the operating pressure range for increasing and decreasing pressure.
S
= 10 Vdc.
Low Cost, Stainless Steel Media Isolated Pressure Sensors
6
6
6
2
2
3
3
3
4
4
4
4
4
4
3
3
3
5
5
5
1
2
7
A
= 25 °C [77 °F]; For SPTmA and SPT4V, Supply V
2
2
4
4
4
4
4
4
Minimum
15.84
3.84
0.96
3.96
148
0.5
8.0
3.0
48
98
-2
Typical
±0.015
±0.010
±0.015
±0.010
±0.015
±0.010
±0.1
±0.5
±0.5
±0.1
±0.1
±0.1
±0.5
±0.5
±1.5
±1.5
±0.1
±0.1
±0.1
±0.5
±0.5
±1.5
±1.5
±0.1
±0.1
1.25
16.0
100
150
0.1
4.5
4.0
1.0
4.0
±1
±1
50
25
0
5
5
S
= 23.5 Vdc ±0.01 Vdc; for SPTmV:
Honeywell Sensing and Control
Maximum
±0.030
±0.030
±0.030
±0.030
±0.25
±0.25
±0.03
±0.25
±0.03
16.16
±1.0
±1.0
±2.0
±2.0
±0.3
±0.3
±1.5
±1.5
±2.5
±2.5
±0.3
±0.3
±1.5
±1.5
±2.5
±2.5
±0.3
±0.3
4.16
1.04
4.04
102
152
2.0
6.0
+2
52
50
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
Unit
Vdc
mV
mV
mV
mV
mA
mA
ms
ms
ms
V
V
3

Related parts for SPT4V3000PA4W02