OHN3075U Optek, OHN3075U Datasheet - Page 2

Board Mount Hall Effect / Magnetic Sensors Hall Effect Sensor

OHN3075U

Manufacturer Part Number
OHN3075U
Description
Board Mount Hall Effect / Magnetic Sensors Hall Effect Sensor
Manufacturer
Optek
Datasheet

Specifications of OHN3075U

Operating Supply Voltage
5 V or 9 V or 12 V
Mounting Style
Through Hole
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 20 C
Maximum Output Current
25 mA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
OHN3075U
Quantity:
4 000
Hallogic Hall-effect Sensors
OH090U, OH180U, OH360U
OHN3000 Series, OHS3000 Series
OHN3100 Series, OHS3100 Series
Absolute Maximum Ratings
Electrical Characteristics
OH090U
OH180U
Issue A .3
Page 2 of 9
SYMBOL
SYMBOL
B
B
V
B
B
V
Icc
I
Icc
I
B
B
Notes:
OH
Supply Voltage, Vcc
Storage Temperature Range, T
Operating Temperature Range, T
Lead Soldering Temperature (1/8 in. (3.2 mm) from case for 5 sec. with soldering iron)
Output ON Current, I
Output OFF Voltage, V
Magnetic Flux Density, B
t
OH
t
t
t
OP
RP
OL
OP
RP
OL
r
f
r
H
H
f
(1) South pole facing symbolized surface.
10/06
Magnetic Operate Point
Magnetic Release Point
Magnetic Hysteresis
Supply Current
Output Saturation Voltage
Output Leakage Current
Output Rise Time
Output Fall Time
Magnetic Operate Point
Magnetic Release Point
Magnetic Hysteresis
Supply Current
Output Saturation Voltage
Output Leakage Current
Output Rise Time
Output Fall Time
Uni-Polar
Uni-Polar
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
PARAMETER
PARAMETER
SINK
OUT
(Vcc = 4.5 V to 24 V, T
(1)
S
(1)
(T
Phone: (972) 323-2200 or (800) 341-4747
A
A
=25°C unless otherwise noted)
MIN
-100
MIN
70
20
10
0
-
-
-
-
-
0
-
-
-
-
-
TYP
0.21
0.10
140
100
TYP
0.21
0.10
180
0.5
100
40
0.5
90
65
25
6
6
A
= 25° C unless otherwise noted)
MAX
10.0
1.00
1.00
MAX
290
230
120
300
10.0
1.00
1.00
180
100
100
300
9
9
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
UNITS
Gauss
Gauss
Gauss
UNITS
Gauss
Gauss
Gauss
mA
mV
µA
µs
µs
mA
mV
µA
µs
µs
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Vcc = 24 V, Output Off
Vcc = 4.5 V, I
Vcc = 24 V, V
R
OHN30_ _U
OHS30_ _U
OH090/180/360U
Vcc = 4.5 V, I
Vcc = 24 V, V
R
Vcc = 24 V, Output Off
L
L
= 820 Ω, C
= 820 Ω, C
TEST CONDITIONS
TEST CONDITIONS
OL
OUT
L
OL
OUT
L
= 20 pF, Vcc = 14 V
= 20 pF, Vcc = 14 V
= 20 mA, B ≥ 290 Gauss
= 20 mA, B ≥ 180 Gauss
= 24 V, B ≤ 0 Gauss
= 24 V, B ≤ -100 Gauss
-65°C to +160°C
-40°C to +125°C
-40°C to +150°C
-20°C to +85°C
Unlimited
260°C
25 mA
25 V
25 V
(1)

Related parts for OHN3075U