10INCH-G-HGRADE-MINI All Sensors Corporation, 10INCH-G-HGRADE-MINI Datasheet - Page 4

no-image

10INCH-G-HGRADE-MINI

Manufacturer Part Number
10INCH-G-HGRADE-MINI
Description
Board Mount Pressure Sensors 0-10" H2O 20mV 0.5% 16V supply no port
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 10INCH-G-HGRADE-MINI

Operating Pressure
0 in H2O to 10 in H2O
Pressure Type
Gauge
Accuracy
+/- 0.25 %
Mounting Style
Through Hole
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
16 V
Package / Case
SIP
Output Voltage
20 mV
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specification Notes
NOTE
NOTE
NOTE
NOTE
NOTE
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied
is typically less than 100 useconds.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Performance Characteristics for 30 PSI-G-HGRADE-MINI
Performance Characteristics for 15 PSI-A-HGRADE-MINI
Performance Characteristics for 100 PSI-G-HGRADE-MINI
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero gage pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 4
Span Shift (0°C-70°C), note 2
Parameter, note 1
Operating Range, absolute pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 4
Span Shift (0°C-70°C), note 2
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero gage pressure
Offset Temperature Shift (0°C-70°C), note 2
Linearity, hysteresis error, note 4
Span Shift (0°C-70°C), note 2
UNLESS OTHERWISE SPECIFIED
1: A
2: S
3: S
4: M
5: T
HIFT IS RELATIVE TO
HIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE
HE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE
LL PARAMETERS ARE MEASURED AT
EASURED AT ONE
-
HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT
25°C.
. P
RESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO
12.0
VOLT EXCITATION
,
FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE
.
M i n i m u m
.
M i n i m u m
M i n i m u m
1-25
89.1
89.1
99.0
.
P
N o m i n a l
N o m i n a l
N o m i n a l
ORT
100.0
100.0
B.
30.0
90.0
0.25
15.0
90.0
0.25
0.25
M a x i m u m
M a x i m u m
M a x i m u m
101.0
90.9
±0.5
±0.5
90.9
±0.5
±0.5
±0.5
±0.5
0.5
0.5
0.5
±1
±1
±1
Units
Units
Units
PSIA
PSIG
PSIG
%fs
%fs
%fs
%fs
mV
mV
mV
%fs
%fs
mV
mV
mV
mV
mV
mV
1

Related parts for 10INCH-G-HGRADE-MINI