12PA12-Y Honeywell, 12PA12-Y Datasheet

no-image

12PA12-Y

Manufacturer Part Number
12PA12-Y
Description
Switch Hardware ROCKER SWITCH YELL
Manufacturer
Honeywell
Datasheet

Specifications of 12PA12-Y

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Manual Switches
Sealed Rocker Switches
GENERAL INFORMATION
MICRO SWITCH NR Series Rocker Switches meet severe environment application
needs for a rugged, cost-effective manual switch. They combine the advantages of
toggle switch circuit versatility with pushbutton control.
Quality construction features include a premolded elastomer seal between the actua-
tor and bushing and an elastomer cover/case gasket seal. Also, the terminal inserts are
molded into the high impact strength thermoplastic case.
Complete sealing of the switching chamber enables compliance with UL 508, para-
graph 13.3 hosedown test. These switches can be used where panels are subjected to
periodic splash and washdowns, such as are common to food and beverage equip-
ment. They will also withstand exposure to heavy accumulations of eary morning dew
that may condense on the control panel in cabs of vehicles left outdoors overnight.
12PA ROCKER ORDER GUIDE
Note: These listings are used to specify
rockers only.
Honeywell Sensing and Control 1-800-537-6945 USA
Rocker
Color
White
Red
Yellow
Black
Green
Blue
Above Panel Mount
Catalog
Listing
12PA12-W
12PA12-R
12PA12-Y
12PA12-BK
12PA12-G
12PA12-BL
ELECTRICAL RATINGS
In Amperes
Rating
Elect.
Code
1
2
3
4
5
6
1-815-235-6847 International 1-800-737-3360 Canada
Flush Panel Mount
Ind.
12
10
15
10
12
10
28 Volts DC
(See Application Note on next page)
Res.
20
15
20
18
20
18
Lamp
5
4
7
5
5
4
115 VDC
Res.
0.75
0.75
0.75
0.75
0.75
0.75
250 VDC
1. To order flush panel mount switches
FEATURES
HOW TO ORDER
2. To
3. To order rockers, specify listings in
ELECTRICAL RATINGS
L191: 15 amps, 125, 250, 277 VAC;
L192: 10 amps, 125, 250, 277 VAC;
Res.
0.5
0.5
0.5
0.5
0.5
0.5
Completely sealed switching
chamber
Colored removable rockers
Choice of flush-panel or above-panel
mounting
Step-design case provides added
space between terminals to help
prevent shorting
1, 2 or 4-pole circuitry
2 or 3 positions, maintained and
momentary action
Spring-loaded actuating mechanism
provides excellent tactile feedback
High impact strength, non-tracking
case enhances electrical stability
Temperature range:
( 40 to 160 F)
UL recognized, File E12252, Vol. 1,
Section 44
CSA certified, File LR4442
CE approved
without rockers, specify the listings in
the NR order guides.
1NR1, 11NR1, 2NR1, 12NR1, 4NR1, and
14NR1 listings in the NR order guides
1NR4-2, 11NR1-2 to 11NR4-2.
switches, change the 1 (after ‘‘NR’’) in
to 4. Example: 1NR1-2W converts to
For 1NR91, 2NR91, and 14NR91 list-
ings add 4 (after the ‘‘NR’’) to specify
the above panel mount version. Exam-
ple: 1NR91-2 becomes 1NR491-2.
the 12PA rocker order guide.
125 VAC; 1 Hp, 250, 277 VAC;
5 amps, 125 VAC ‘‘L’’
125 VAC;
3 amps, 125 VAC ‘‘L’’
specify
Ind.
10
15
15
7
8
8
115 Volts AC
60 & 400 Hz
1
Res.
2
15
15
15
11
15
11
above-panel
Hp, 250, 277 VAC;
123
Lamp
40 to 71 C
3
2
4
2
4
2
NR Series
230 VAC
Res.
mount
6
6
6
6
6
6
1
1
2
4
Hp,
Hp,

Related parts for 12PA12-Y

12PA12-Y Summary of contents

Page 1

... Note: These listings are used to specify rockers only. Rocker Catalog Color Listing White 12PA12-W Red 12PA12-R Yellow 12PA12-Y Black 12PA12-BK Green 12PA12-G Blue 12PA12-BL Honeywell Sensing and Control 1-800-537-6945 USA Flush Panel Mount ELECTRICAL RATINGS In Amperes (See Application Note on next page) Elect ...

Page 2

... Honeywell Sensing and Control 1-800-537-6945 USA Application Note: Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. NR switches use silver cadmium oxide contacts ...

Page 3

... Seated Rocker Switches MOUNTING DIMENSIONS (For reference only) Flush Panel Quick Connect Terminals Solder Terminals Panel Cutout Honeywell Sensing and Control 1-800-537-6945 USA Above Panel Terminal Circuit Identification Flange mounting torque is 10–12 in./lbs. Terminal screw mounting torque is 5 in./lbs. max. ...

Page 4

... Application Note: Honeywell MICRO SWITCH does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. NT/NR switches use silver cadmium oxide contacts. For other options, contact the MICRO SWITCH Application Center at 1-800-537-6945 ...

Page 5

... Locked In Extreme Position Three Positions (Keyway Side Locked Out Of Locked In Center And Center And Extreme Position Extreme Position (Opposite Keyway) (Opposite Keyway) Honeywell Sensing and Control 1-800-537-6945 USA Catalog UL Rating Electrical Listing Code Rating Code Toggle Q-C L191 1 31NT91-2 L191 1 31NT91-3 ...

Page 6

... Top specify above-panel mount rock- ers: add 4 (after the ‘‘NR’’) to specify the above panel version. Example: 31NR91-5 becomes 31NR491-5. ROCKER BUTTONS ORDER GUIDE Rocker Catalog Color Listing White 12PA12-W Red 12PA12-R Yellow 12PA12-Y Black 12PA12-BK Green 12PA12-G Blue 12PA12-BL ...

Page 7

... Flat Base Sealed Toggles and Rockers MOUNTING DIMENSIONS (For reference only) Toggle Switches Bushing mounting torque is 10–15 in./lbs. Honeywell Sensing and Control 1-800-537-6945 USA Rocker Switches, Above Panel Rocker Switches, Flush Panel Flange mounting torque is 10–12 in./lbs. 1-815-235-6847 International 1-800-737-3360 Canada ...

Related keywords