ARD10012M06 Panasonic, ARD10012M06 Datasheet - Page 6

no-image

ARD10012M06

Manufacturer Part Number
ARD10012M06
Description
Coaxial Switches ARD Coaxial Switch
Manufacturer
Panasonic
Datasheet
RD (ARD)
2) SP6T
Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use.
Contact
Rating
Indicator rating
High frequency
characteristics
(Impedance 50Ω)
Electrical
characteristics
Time characteristics
(at 20°C 68°F)
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
*2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
Arrangement
Contact material
Initial contact resistance
Contact
input power
Nominal
operating
power
Contact rating
Initial contact resistance
Min. switching capacity
(Reference value)
V.S.W.R.
(max.)
Insertion loss (dB, max.)
Isolation (dB, min.)
Insulation resistance (Initial)
Breakdown
voltage
(Initial)
Operate time
Shock
resistance
Vibration
resistance
Mechanical
Electrical
Conditions for operation,
transport and storage*
No termination
With termination
Fail-safe
Latching
No termination
With termination
Between open
contacts
Between contact
and coil
Between contact
and earth terminal
Between coil and
earth terminal
Functional
Destructive
Functional
Destructive
High frequency
contact (Hot switch)
Indicator (with
indicator type only)
Item
2
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
With termination
No termination
120 W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*
2W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*
to 1 GHz
Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.)
1.1
85
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Min. 500 m/s
10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.)
1.20
0.2
700mW (4.5V DC), 750mW (12V DC), 900mW (24V DC)
Ambient temperature: –55°C to +85°C
Min. 1,000 m/s
3V DC, 0.1mA (5 × 10
2
Min. 5 × 10
Min. 5 × 10
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
(Half-wave pulse of sine wave: 11ms, detection time: 10µs.)
840mW (4.5V, 12V DC), 970mW (24V DC)
Max. 100mΩ (By voltage drop 6V DC 1A)
10 to 55 Hz at double amplitude of 5mm
1 to 4 GHz
5 VDC, 10 mA, Min. 10
Max. 1Ω (Measured by 5V 100mA)
1.15
80
6
6
Min. 5 × 10
2
(5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm)
(2W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm)
(Half-wave pulse of sine wave: 11ms.)
Approx. 320g
Max. 30V 100mA
Specifications
Gold plating
6
, Reliability level: 10% (3kΩ))
SP6T
6
(at 180 cpm)
11.29oz
6
(at 20 cpm)
4 to 8 GHz
–67°F to +185°F
1.25
1.40
0.3
70
8 to 13 GHz
1.35
1.50
0.4
65
1