HF3 96 S Tyco Electronics, HF3 96 S Datasheet - Page 7

RF (Radio Frequency) Relays HI FREQ SPDT 50 OHM 140MW 12V BIST 2COIL

HF3 96 S

Manufacturer Part Number
HF3 96 S
Description
RF (Radio Frequency) Relays HI FREQ SPDT 50 OHM 140MW 12V BIST 2COIL
Manufacturer
Tyco Electronics
Datasheet

Specifications of HF3 96 S

Contact Form
1 Form C (SPDT)
Coil Voltage
12 VDC
Coil Type
Latching, 2 Coils
Power Consumption
140 mW
Termination Style
SMD/SMT
Coil Current
2 A
Contact Carry Current
2 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2-1462051-6
* Duration may be shorter depending on pulse shape, voltage applied and ambiente temperature
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Contact Data
Insulation
General Data
Number of contacts and type
Contact material
Limiting continuous current at max. ambient temperature
Maximum switching current
Maximum swichting voltage
Maximum switching capacity
Initial contact resistance at 10 mA / 20 mV
Mechanical endurance
Max. Continuous RF-power
Peak RF-power
Insulation resistance at 500 VDC
Dielectric test voltage (1 min)
Surge voltage resistance according to FCC 68 (10 / 160 μs)
Operate time at U
Reset time (latching) at Unom typ. / max.
Release time without diode in parallel (non-latching) typ./max.
Release time with diode in parallel (non-latching) typ./max.
Duration of set / reset pulse (latching) min.
Bounce time at closing contact typ. / max.
Maximum switching rate without load
Ambient temperature
Thermal resistance
Maximum permissable coil temperature
Vibration resistance (function)
Shock resistance, half sinus, 11 ms
Degree of protection / Environmental protection
Needle flame test
Mounting position
Processing information
Weight (mass)
Terminal surface
Moisture sensitive level (JEDEC J-STD-020B)
Resistance to soldering heat
between coil and contacts
between open contacts
and (2 / 10 μs)
between coil and contacts
between open contacts
nom
typ./max.
AXICOM
Telecom-, Signal and RF Relays
HF3 S Relay
100 W @ 3 GHz (with appropriate cooling, only)
150 W @ 2 GHz (with appropriate cooling, only)
application time 20 s, burning time < 15 s
Ultrasonic cleaning is not recommended
300 W (with appropriate cooling, only)
immersion cleanable, IP 67 / RT III
60 W / 62.5 VA / 50 W (2.5 GHz)
1 changeover (SPDT)
Silver, gold-covered
220 Vdc / 250 Vac
-55 °C ... +85 °C
150 G (damage)
50 operations/s
50 G (function)
10
10 to 1000 Hz
265 °C/10 s
3 ms / 5 ms
3 ms / 5 ms
2 ms / 4 ms
4 ms / 6 ms
1 ms / 3 ms
1000 Vrms
< 165 K/W
max. 3.0 g
< 100 mΩ
> 100 MΩ
7
600 Vrms
SnCu 0.7
1500 V
1000 V
125 °C
operations
20ms*
MSL 3
35 G
any
2 A
2 A
108-98021 Rev. B
7 of 12