G6ZU-1F-DC9 Omron, G6ZU-1F-DC9 Datasheet
G6ZU-1F-DC9
Specifications of G6ZU-1F-DC9
Related parts for G6ZU-1F-DC9
G6ZU-1F-DC9 Summary of contents
Page 1
... Notes: 1. When ordering, add the rated coil voltage to the model number. Example: G6Z-1PE-A-DC12 2. When ordering tape packing (surface mount models), add "-TR" to the model number. Example: G6ZU-1FE-TR-DC12 Tape packing "-TR" is not part of the relay model number. Therefore not marked on the relay case. ...
Page 2
... Application Examples These Relays can be used for switching signals in media equipment. • Wire communications: Cable TV (STB and broadcasting infrastructure), cable modems, and VRS (video response systems) • Wireless communications: Transceivers, ham radios, ETC, ITS, high-level TV, satellite broadcasting, text multiplex broadcasting, mobile phone stations, TV broadcasting facilities, community antenna systems and car navigation systems • ...
Page 3
... Non-latching, Standard and Reverse-contact Models G6Z-1P(E), G6Z-1F(E) Rated Rated voltage current (VDC) (mA) 3 66.7 4.5 44.4 5 40.0 9 22.2 12 16.7 24 8.3 Single Coil Latching Models G6ZU-1P(E), G6ZU-1F(E) Rated Rated voltage current (VDC) (mA) 3 66.7 4.5 44.4 5 40.0 9 22.2 12 16.7 24 8.3 Dual Coil Latching Models G6ZK-1P(E), G6ZK-1F(E) ...
Page 4
... Ambient temperature (°C) G6Z 344 High-frequency Relay Non-latching Single coil latching models G6Z-1P(E), G6Z-1F(E) G6ZU-1P(E), G6ZU-1F(E) 100 mΩ max max. (approx. 3.5 ms max. (approx. 2.5 ms max. (approx 2.5 ms) --- 12 ms 100 MΩ min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 min. 500 VAC, 50/60 Hz for 1 min. ...
Page 5
... Operating frequency (×10 operations) (Average value) + +20 +10 0 −10 −20 Sample: G6Z-1P 5 VDC Must operate voltage Number of Relays: 5 Must release voltage −30 −1,200 −800 −400 0 400 800 1,200 External magnetic field (A/m) (Average value) + +20 +10 0 −10 −20 Sample: G6Z-1P 5 VDC ...
Page 6
... Frequency (MHz) 30 Must operate bounce time Must release bounce time 25 Sample: G6Z-1P 75 Ω 5 VDC 20 Number of Relays 0.5 1.0 1.5 2.0 Time (ms) (Average value (initial value)) 0 1.7 Sample: G6Z-1PE 75 Ω 5 VDC with terminating resistance 1.6 Return loss 1 ...
Page 7
... High-frequency Relay Terminal Arrangement/Internal Connections (Bottom View) G6Z-1PE Orientation mark 1 7 − G6Z-1PE-R Orientation mark 1 7 − G6ZU-1PE Orientation mark 1 7 − − Terminal Arrangement/Internal Connections (Bottom View) G6Z-1PE-A Orientation mark 1 7 − G6ZU-1PE-A Orientation mark 1 7 − − G6Z 347 ...
Page 8
... Terminal Arrangement/Internal Connections (Bottom View) G6Z-1P Orientation mark − G6ZU-1P Orientation mark − − Terminal Arrangement/Internal Connections (Bottom View) G6Z-1P-A Orientation mark − G6ZU-1P-A Orientation mark − − Terminal Arrangement/Internal Connections (Bottom View) Orientation mark − + − ...
Page 9
G6ZK-1PE-A 20 8.6 8.9 3 0.2 2.54 10-0.6 (Coil 7.62 7.62 terminal) 15.24 Note: Each value has a tolerance of ±0.3 mm. G6ZK-1P 20 8.6 8.9 3 9-0.6 0.2 (Coil 2.54 7.62 3-0.4 terminal) 7.62 15.24 Note: Each value has ...
Page 10
... Terminal Arrangement/Internal Connections (Top View) G6Z-1FE Orientation mark − G6ZU-1FE Orientation mark − − Terminal Arrangement/Internal Connections (Top View) G6Z-1FE-A Orientation mark − G6ZU-1FE-A Orientation mark − − Terminal Arrangement/Internal Connections (Top View) G6Z-1F Orientation mark − G6ZU-1F Orientation mark − − R ...
Page 11
... Seven, 1.1 Mounting Dimensions (Top View) Tolerance: ±0.1 mm 15.24 7.62 2.3 2.54 8.3 Ten, 1.1 0.18 High-frequency Relay Terminal Arrangement/Internal Connections (Top View) G6Z-1F-A Orientation mark − G6ZU-1F-A Orientation mark − − Terminal Arrangement/Internal Connections (Top View) Orientation mark − ...
Page 12
G6ZK-1F 20 8.6 0.2 9.3 (Coil terminal) Nine, 0.6 9.6 2.54 Three, 0.4 7.62 15.24 Note 1: Each value has a tolerance of ±0.3 mm. 2: The coplanarity of the terminals is 0.1 mm max. G6ZK-1F-A 20 8.6 0.2 9.3 ...
Page 13
... Note: The radius of the unmarked corner is 0.3 mm. Do not quench the terminals after mounting. Clean the Relay using alcohol or water no hotter than 40°C max. The thickness of cream solder to be applied should be between 150 and 200 μm on OMRON’s recommended PCB pattern. Correct Soldering Relay Terminal ...
Page 14
... High-frequency Characteristics Measurement Method and Measurement Substrate High-frequency characteristics for the G6Z are measured in the way shown below. Consult your OMRON representative for details on 50-Ω models. Measurement Method for 75-W Models G6Z Network vector analyzer ...
Page 15
... Latching Relay Mounting Make sure that the vibration or shock that is generated from other devices, such as Relays, on the same panel or substrate and imposed on the Latching Relay does not exceed the rated value, oth- erwise the set/reset status of the Latching Relay may be changed. ...
Page 16
... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...