H5CN-XZNS AC100-240 Omron, H5CN-XZNS AC100-240 Datasheet - Page 4

no-image

H5CN-XZNS AC100-240

Manufacturer Part Number
H5CN-XZNS AC100-240
Description
Controllers Timer Digital LED
Manufacturer
Omron
Datasheet

Specifications of H5CN-XZNS AC100-240

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Life-test Curve (Reference Values)
A maximum current of 0.15A can be switched at 125 VDC (cosφ = 1)
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both
cases, a life of 100,000 operations can be expected. The minimum
applicable load is 10 mA at 5 VDC (failure level: P reference value).
1,000
700
500
300
100
70
50
30
10
7
5
0
250 VAC cosφ =0.4
1
Load current (A)
30 VDC cosφ =1
30 VDC L/R = 7 ms
2
250 VAC cosφ =1
3
4
H5CN