E5EZ-PRR
Specifications
Characteristics
Note: 1. The indication accuracy of K thermocouples in the 200 to 1300°C range, T and N thermocouples at a temperature of 100°C max., and
Indication accuracy
Influence of temperature
Influence of voltage
(See note 2.)
Proportional band (P)
Integral time (I)
Derivative time (D)
Control period
Manual reset value
Alarm setting range
Sampling period
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight
Memory protection
EMC
Approved standards
Conformed standards
(See note 2.)
2. For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring
U and L thermocouples at any temperature is 2°C 1 digit maximum. The indication accuracy of the B thermocouple at a temperature
of 400°C max. is not specified. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is 3°C 1 digit
max.
(TDK: ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller.
Thermocouple:
( 0.5% of indicated value or 1°C, whichever is greater) 1 digit max. (See note 1.)
Platinum resistance thermometer:
( 0.5% of indicated value or 1°C, whichever is greater) 1 digit max.
Analog Input: 0.5% FS 1 digit max.
Potentiometer Input: 5% FS 1 digit max.
R, S, and B thermocouple inputs:
( 1% of PV or 10°C, whichever is greater) 1 digit max.
Other thermocouple inputs:
( 1% of PV or 4°C, whichever is greater) 1 digit max.
* 10°C for -100°C or less for K sensors
Platinum resistance thermometer inputs:
( 1% of PV or 2°C, whichever is greater) 1 digit max.
Analog inputs:
( 1% of FS) 1 digit max.
0.1 to 999.9 EU (in units of 0.1 EU)
0 to 3999 s (in units of 1 s)
0 to 3999 s (in units of 1 s)
1 to 99 s (in units of 1 s)
0.0% to 100.0% (in units of 0.1%)
500 ms
20 M min. (at 500 VDC)
2000 VAC, 50 or 60 Hz for 1min (between terminals of different charge)
10 to 55 Hz, 20 m/s
100 m/s
Approx. 260 g
EEPROM (non-volatile memory) (number of writes: 100,000 operations)
Emission enclosure:
Emission AC mains:
Immunity ESD:
Immunity RF interference:
Immunity-conducted disturbance: EC61000-4-6 (GB/T 17626.6): 3 V(0.15-80 MHz) (series 3)
Surges (shocks):
UL61010C-1,CSA C22.2 No.1010.1
EN61326, EN61010-1 (IEC61010-1)
1999 to 9999 (decimal point position depends on input type)
2
, 3 times each in X, Y, and Z directions
2
for 10min each in X,Y, and Z directions
With floating control, 1 to 3999 s
EN55011 (GB/T 6113.1, 2)
EN55011 (GB/T 6113.1, 2)
IEC61000-4-2 (GB/T 17626.2) 4 kV contact discharge (series 2)
IEC61000-4-3 (GB/T 17626.3): 10 V/m, 80 MHz-1 GHz (series)
IEC61000-4-5 (GB/T 17626.5): 2 kV power supply line (series 3)
1 group, type A
1 group, type A (See note 2.)
6 kV air discharge (series 3)
1 kV I/O signal line (series 4)