Specifications of ZS-DSU11

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Multi-Controller
Centralized Controller Information Calculations
Transfers data between multi-connected Controllers and performs high-speed multiprocessing.
High-speed Connections for Up To 9 Controllers
See the difference in applications requiring multipoint measurement, such as thickness, steps, and flatness
measurements. Connect up to 9 Controllers with the fastest high-speed bus in the industry. Digital processing
prevents data dropouts to provide the capability to measure exactly what is seen.
Sampling speed with 3 Controllers connected: 110 μs, Sampling speed with 9 Controllers connected: 380 μs
Note: When using communications commands.
Processing Enabled by the Multi-Controller
Flatness Calculations
Calculating the difference between the
maximum and minimum values.
Multipoint Thickness Calculations
Calculating the difference between pairs of points.
Multipoint measurement
(flatness of resins or metals)
Calculation:
Task 1 = Max. (A, B, ···) − Min. (A, B, ···)
A
A
B
Sensor Head
C
D
C
B
E
F
Number of Sensor
Controllers: 2, 4, 6, or 8
Calculation:
Individual judgments
TASK1 = K + (A − B)
TASK2 = K + (C − D)
TASK3 = K + (E − F)
Number of Sensor
Controllers: 3 to 9
ZS-MDC
Reference Step Calculations
Calculating the difference between a
reference point (A) and other points.
Average Height Calculations
Calculating the average surface height.
Calculation: Task 1 = Average (A, B, C, ···)
A
A
C
C
ZS-MDC
Multi-Controllers
B
B
Number of Sensor
Controllers: 3 to 9
Calculation:
Individual judgments
Number of Sensor
Controllers: 2 to 9
TASK1 = A − B
TASK2 = A − C
···
Processing results
Relative Step Calculations
Calculating the difference between all points.
Warp Calculations
Calculating warping of selected sides
A
A
Calculation: Task 1 = B − (A + C)/2
B
C
B
USB
C
Monitor connected Controllers
together
Number of Sensor
Controllers: 3 to 9
Calculation:
Individual judgments
TASK1 = A − B
TASK2 = B − C
TASK3 = C − A
SmartMonitor
Number of Sensor
Controllers: 3
Twisting Calculations
Calculating twisting between opposing sides.
User-set Calculations
Formulas can be flexibly set.
B
Calculation: TASK1 = (A − B) − (D − C)
[K + mX + nY]
A
C
D
Number of Sensor
Controllers: 4
Smart Se ns or
Multipoint measurement
Multi-calculations of Data
High-speed data transfer
Advanced technology is carried
17