CY7C66113C-LFXCT Cypress Semiconductor Corp, CY7C66113C-LFXCT Datasheet - Page 37

no-image

CY7C66113C-LFXCT

Manufacturer Part Number
CY7C66113C-LFXCT
Description
IC MCU 8K USB HUB 4 PORT 56VQFN
Manufacturer
Cypress Semiconductor Corp
Datasheet

Specifications of CY7C66113C-LFXCT

Applications
USB Hub/Microcontroller
Core Processor
M8
Program Memory Type
OTP (8 kB)
Controller Series
USB Hub
Ram Size
256 x 8
Interface
I²C, USB, HAPI
Number Of I /o
31
Voltage - Supply
4 V ~ 5.25 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
56-VQFN Exposed Pad, 56-HVQFN, 56-SQFN, 56-DHVQFN
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
56
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
CY3649 - PROGRAMMER HI-LO USB M8428-1339 - KIT LOW SPEED PERSONALITY BOARD
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
USB Upstream Port Status and Control
USB status and control is regulated by the USB Status and Control Register, as shown in
during reset.
USB Status and Control
Bits[2..0]: Control Action
Set to control action as per
the upstream port to be driven manually by firmware. For normal
USB operation, all of these bits must be cleared.
how the control bits affect the upstream port.
Table 13. Control Bit Definition for Upstream Port
Bit 3: Bus Activity
This is a “sticky” bit that indicates if any non idle USB event has
occurred on the upstream USB port. Firmware should check and
clear this bit periodically to detect any loss of bus activity. Writing
a ‘0’ to the Bus Activity bit clears it, while writing a ‘1’ preserves
the current value. In other words, the firmware clears the Bus
Activity bit, but only the SIE can set it.
Bits 4 and 5: D– Upstream and D+ Upstream
These bits give the state of each upstream port pin individually:
1 = HIGH, 0 = LOW.
Document Number: 38-08024 Rev. *D
Bit #
Bit Name
Read/Write
Reset
Control Bits
000
001
010
011
100
101
110
7
Endpoint
Size
R/W
0
111
Table
6
Endpoint
Mode
0
R/W
13.The three control bits allow
Not Forcing (SIE Controls Driver)
Force D+[0] HIGH, D–[0] LOW
Force D+[0] LOW, D–[0] HIGH
Force SE0; D+[0] LOW, D–[0] LOW
Force D+[0] LOW, D–[0] LOW
Force D+[0] HiZ, D–[0] LOW
Force D+[0] LOW, D–[0] HiZ
Force D+[0] HiZ, D–[0] HiZ
Figure 42. USB Status and Control Register
5
D+
Upstream
0
R
Table 13
shows
4
D– Upstream Bus Activity
R
0
Bit 6: Endpoint Mode
This bit used to configure the number of USB endpoints. See
USB Device Endpoints
Bit 7: Endpoint Size
This bit used to configure the number of USB endpoints. See
USB Device Endpoints
The hub generates an EOP at EOF1 in accordance with the USB
1.1 Specification, Section 11.2.2.
3
R/W
0
Control Action
CY7C66013C, CY7C66113C
Figure
2
Control
Action
Bit 2
R/W
0
for a detailed description.
for a detailed description.
42. All bits in the register are cleared
1
Control
Action
Bit 1
R/W
0
ADDRESS
Page 37 of 59
0
Control
Action
Bit 0
R/W
0
0x1F