EP2S130F1020C3 Altera, EP2S130F1020C3 Datasheet - Page 95

no-image

EP2S130F1020C3

Manufacturer Part Number
EP2S130F1020C3
Description
IC STRATIX II FPGA 130K 1020FBGA
Manufacturer
Altera
Series
Stratix® IIr
Datasheet

Specifications of EP2S130F1020C3

Number Of Logic Elements/cells
132540
Number Of Labs/clbs
6627
Total Ram Bits
6747840
Number Of I /o
742
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1020-FBGA
Family Name
Stratix II
Number Of Logic Blocks/elements
132540
# I/os (max)
742
Frequency (max)
778.82MHz
Process Technology
90nm (CMOS)
Operating Supply Voltage (typ)
1.2V
Logic Cells
132540
Ram Bits
6747840
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1020
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant
Other names
544-2158

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2S130F1020C3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S130F1020C3
Manufacturer:
ALTERA
0
Part Number:
EP2S130F1020C3K
Manufacturer:
ALTERA
0
Part Number:
EP2S130F1020C3N
Manufacturer:
ALTERA
Quantity:
238
Part Number:
EP2S130F1020C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S130F1020C3N
Manufacturer:
ALTERA
0
Part Number:
EP2S130F1020C3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2S130F1020C3N
0
Altera Corporation
May 2007
Notes to
(1)
(2)
(3)
(4)
SSTL-2 Class I and II
Table 2–16. Stratix II Supported I/O Standards (Part 2 of 2)
This I/O standard is only available on input and output column clock pins.
This I/O standard is only available on input clock pins and DQS pins in I/O banks 3, 4, 7, and 8, and output clock
pins in I/O banks 9,10, 11, and 12.
V
The clock input pins supporting LVDS on banks 3, 4, 7, and 8 use V
dependency on the V
1.2-V HSTL is only supported in I/O banks 4,7, and 8.
CCIO
I/O Standard
Table
is 3.3 V when using this I/O standard in input and output column clock pins (in I/O banks 9, 10, 11, and 12).
2–16:
f
CCIO
Voltage-referenced
level of the bank.
For more information on I/O standards supported by Stratix II I/O
banks, refer to the Selectable I/O Standards in Stratix II & Stratix II GX
Devices chapter in volume 2 of the Stratix II Device Handbook or the
Stratix II GX Device Handbook.
Stratix II devices contain eight I/O banks and four enhanced PLL external
clock output banks, as shown in
right and left of the device contain circuitry to support high-speed
differential I/O for LVDS and HyperTransport inputs and outputs. These
banks support all Stratix II I/O standards except PCI or PCI-X I/O pins,
and SSTL-18 Class II and HSTL outputs. The top and bottom I/O banks
support all single-ended I/O standards. Additionally, enhanced PLL
external clock output banks allow clock output capabilities such as
differential support for SSTL and HSTL.
Type
Voltage (V
Input Reference
1.25
REF
) (V)
Figure
CCINT
Voltage (V
Stratix II Device Handbook, Volume 1
Output Supply
for LVDS input operations and have no
2–57. The four I/O banks on the
2.5
CCIO
) (V)
Stratix II Architecture
Board Termination
Voltage (V
1.25
TT
) (V)
2–87

Related parts for EP2S130F1020C3