Schedule of Tests
Required for Qualification
Approval
Visual Examination
Dimensions, outline mass(including
contacts) Compatability Gauging
procedure
Polarization
Engaging and separating force, connector
Contact Holding Force
Sealing (air pressure)
Sealing Hermetic
Contact Resistance
Housing (Shell) Continuity
Insulation Resistance
Voltage Proof
Soldering
Bumping
Vibration
Shock
Acceleration (Steady State)
Rapid Change of Temperature
Climatic Sequence
Flammability
Damp Heat (Steady State)
Tests
Engagement max: 0,90 Nm (8.0 lbf.in.) to
4,97 Nm (44 lbf.in.) according to shell size.
Separation min: 0,22 Nm (2.0 lbf.in.) to 1,58
Nm (14.0 lbf.in.) according to shell size.
0,21 N (0.047 lbf) min.size 20
0,56 N (0.126 lbf)min. size 16
Max leakage 28,53 uNm/s (1 cm3/h), 1
bar (14.5 p.s.i.) differential.
Hermetic receptacles have a max leak of 0.1 micron
cubic foot per hour (1 x 10-6Cm3/s)
5 milliohms max.
200 milliohms max. 5 milliohms max.
grounding spring styles.
5,000 Megaohms at 500 - 50 V d.c.
See page 7. Duration
As BS 9520: 1974, Clause 1.2.6.6,
Method 2.
As BS 9520: 1974, Clause 1.2.6.1. 4,000
-10 bumps / 390m / s2 (40 gn).
As BS 9520: 1974, Clause 1.2.6.2.1. Procedure A. 10 Hz
to 5000 Hz, 0.75 mm / 10 gn.
As BS 9520: 1974, Clause 1.2.6.3. 981
m/s2 (100 g n).
As BS 9520: 1974, Clause 1.2.6.4. 490
m/s2 (50 gn).
As BS 9520: 1974, Clause 1.2.6.7. -550
C to - 1250 C.
As BS 9520: 1974, Clause 1.2.6.11.
Severity 55/125/56.
As BS 9520: 1974, Clause 1.2.6.8. Direct
flame applied, duration 1 minute.
As BS 9520: 1974, Clause 1.2.6.14.
Severity 56 days.
Brief Description