AQ2A2-C2-T24VDC Panasonic Electric Works, AQ2A2-C2-T24VDC Datasheet - Page 7

AQ2A2-C2-T24VDC

Manufacturer Part Number
AQ2A2-C2-T24VDC
Description
Manufacturer
Panasonic Electric Works
Datasheet

Specifications of AQ2A2-C2-T24VDC

Input Type
DC
Output Type
AC
Input Voltage (max)
26.4V
Output Voltage (max)
250V
Output Current
2A
Isolation Voltage
3kV
Output Device
Triac
Pin Count
4
Mounting
Through Hole
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / Rohs Status
Compliant
AQ8
NOTE
1. When used for the load less than
rated
In case of the load current less than
rated, malfunction may result from the
residual voltage across the both ends of
the load even if the solid state relay is
turned off. Use a dummy resistor as a
countermeasure.
The total of the current through the
resistor and the load current must exceed
the min. rated load current.
In case the dummy resistor is not used,
keep in mind that the residual voltage
becomes as follows:
Example:
For the inductive load by the 20 mA load
current and the 200 V AC load voltage,
the load impedance becomes 10 k Ω and
Ve/V = 14% is estimated from the right
above graph. Accordingly, the 28 V
voltage remains across the both ends of
the load when the solid state relay is
turned off.
For Cautions for Use.
SSR
1
2
Load
R
0
Dummy resistor
Load
power
source
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
• Characteristics of residual voltage vs.
load impedance
2. when the terminal is bent
Care shall be taken neither to apply
mechanical stresses to the mold area of
the solid state relay nor to bend the
terminal 45 degrees or more.
Ve
V
(%)
×
100
100
80
60
40
20
Solid
state relay
0
Ve: Residual voltage
V: Power voltage
f = 60Hz
SSR
1
2
10
Load
Ve
20
Max.
45°
V
Solder
Printed board
30
Power factor: 1
(resistor load)
Power factor: 0.4
(induction load)
40
50

Related parts for AQ2A2-C2-T24VDC