CFD30J4 Cooper/Bussmann, CFD30J4 Datasheet

no-image

CFD30J4

Manufacturer Part Number
CFD30J4
Description
Manufacturer
Cooper/Bussmann
Type
Disconnect Switchr
Datasheet

Specifications of CFD30J4

Pole Throw Configuration
4P
Current Rating (max)
30A
Lead Free Status / Rohs Status
Not Compliant
Disconnect Switches
Catalog
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Related parts for CFD30J4

CFD30J4 Summary of contents

Page 1

... Disconnect Switches Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Catalog ...

Page 2

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 3

... Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Table of Contents Fusible Disconnect Switches.....................................Page 2 Non-Fusible Disconnect Switches...........................Page 29 Enclosed Fusible Disconnect Switches..................Page 69 Enclosed Non-Fusible Disconnect Switches..........Page 79 Index by Part Number ............................................... Page 88 Bussmann ® ...

Page 4

... Mechanical interlock Electrical interlock — Standard • = Available — = Not available UL listed switches are also CSA approved. 1000V IEC 408 2 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com CFD100J3 FD200J3 ...

Page 5

... Bussmann CDS180S + Terminal lugs Wire Wire Catalog 480V 600V size type 15 20 #18 – CFD30J3 15 20 #18 – CFD30CC3 15 20 #18 – CFD30J4 15 20 #18 – CFD30CC4 mm) Weight Defeatable Padlockable (lbs.) — Yes 0.16 — Yes 0.16 Yes Yes 0.16 Yes Yes 0. mm) Mounting depth ...

Page 6

... Handles & Shafts for 30A Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft Pistol handles — for use with shafts BDH104,106 1,3R,4,4X,12 1,3R,4,4X,12 BDH105, 107 Shafts — for use with pistol handles CDS__ __P Direct mount handle — mounts directly to switch, no shaft necessary ...

Page 7

... Accessories for 30A Fusible Disconnect Switches CFD30J3 with auxiliaries CFDZX171 NDNA100 BDZD48 CXBY67121 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Auxiliary contacts Description For use on: Form C 1 N.O. & 1 N.C. ...

Page 8

... One conversion mechanism • Two disconnect switches • One 5 mm shaft Mechanical interlock — BDZW4 Mechanical interlock mechanism prevents both switches from being in the "ON" position at the same time. Equipment required for a complete installation: • One conversion mechanism • Two disconnect switches • ...

Page 9

... CFD60J3 CFD100J3 BDH58,60 BDH59,61 BDS__ BDST_ Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com CFD60J3 + 60 – 100 Amp switches, 600V UL UL Maximum horsepower rating general Fuse purpose type amp rating ...

Page 10

... Accessories for 60A – 100A Fusible Disconnect Switches Terminal lug kit BDTL24 Auxiliary contacts CDAUX10, CDAUX01K Replacement fuse clip CFC60J CFCVR100 Replacement fuse covers Terminal shroud CFTS100 Terminal poles CFZ1 DIN rail NDNA100 “T” type fuse adapter kit BDTA1 8 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 11

... Accessories for 60A – 100A Fusible Disconnect Switches CDETL-ZW16 BDZX167 BDZW9S CDZK19 (X=6MM) Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Locking accessories Description For use on: Cam attachment for Kirk Key, Castell, Lowe & ...

Page 12

... BDZW1 • One conversion mechanism • Two disconnect switches Mechanical interlock — BDZW10 Mechanical interlock mechanism prevents both switches from being in the "ON" position at the same time. Equipment required for a complete installation: • One conversion mechanism • Two disconnect switches • Two handles • ...

Page 13

... FD400J3 FD600J3 FD800L3 BDH112 BDH113 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com FD200J3 + BDS280 200 – 800 Amp switches, 600V UL UL general Fuse purpose type amp rating 600V 200V ...

Page 14

... Accessories for 200A – 800A Fusible Disconnect Switches Shafts — For use on FD200J_ – FD400J_ BDS__ For use on FD600J_ – FD800J_ BDS_45 Twisted shafts — Rotates handle 45° BDTL25 BDTL26 For use on FD200J_ – FD400J_ For use on FD600J_ – FD800J_ BDTL27 ...

Page 15

... Accessories for 200A – 800A Fusible Disconnect Switches BDAUX_ 200A & 400A 600A & 800A Switches Switches BDZX213 BDZX190 BDZX271 BDZX272 BDZX216 BDZX196 BDZX191 BDZX273 BDZX197 BDZX204 BDT5F_ BDTP85 BDTP88 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 16

... Accessories for 200A – 800A Fusible Disconnect Switches Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and Ronis interlock. For adapting to the interlock system. The interlock is not included. Electrical interlock Closed circuit principle for interlocking the switch movement. When the ...

Page 17

... Three BDZW95 shaft extension couplers • Three shafts Mechanical interlock — BDZW3, BDZW14, BDZW15 Mechanical interlock mechanism prevents both switches from being in the "ON" position at the same time. Equipment required for a complete installation: • One conversion mechanism • Two disconnect switches • ...

Page 18

... UL Fuse Class J, CC, T For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug Side operated switches — 3 pole amp rating CFD60J3S Handles For use with CFD30J3S & CFD30CC3S For use with CFD60J3S & CFD100J3S CFD100J3S For use with FD200J3-S & FD400J3-S — ...

Page 19

... BDFHNHS__ BDFHS__ BDTL24 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com CFD30J3F + Flange operated switches — 3 pole UL UL Maximum horsepower rating general fuse purpose type amp rating ...

Page 20

... Wire range AWG #22 – 14/#18 – 14 The following UL Listed switches are also CSA approved. Terminal torques are 35lb. in. for wire sizes #14 – #10 and 45lb. in for wire sizes #8 – #4. 18 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com UL & ...

Page 21

... Ambient temperature 60°C: derating 20 percent. Mounting on ceiling: derating 10 percent. Mounting on wall, horizontal fuses: derating 8 percent. The ambient air temperature does not exceed +40°C and its average over a period of 24h does not exceed +35°C according to IEC 947. For 30A switches, use 2 parallel contacts in series. Available on request. ...

Page 22

... IEC Technical Data for Fusible Disconnect Switches CFD30CC3 – FD800L3 Catalog number 3 pole CFD30_3 Rated breaking capacity in category AC-23A 500V A 256 690V A 256 Rated breaking capacity/poles in series in category DC-23 <220V A 128/2 440V A 128/4 500 – 750V A — 1000V A — Rated conditional short-circuit current r.m.s. ...

Page 23

... Approximate Dimensions for Fusible Disconnect Switches CFD30J3 – CFD60J3 CFD30J3 & CFD30CC3 0.93 23.5 1.83 46.5 1.52 38.5 CFD60J3 3.94 100 1.97 50 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 3 ...

Page 24

... Approximate Dimensions for Fusible Disconnect Switches CFD100J3 – FD200J3 CFD100J3 6.67 169.5 4.80 122 4.35 110.5 1.42 36.0 1.61 1.60 1.38 41.0 40.5 35 5.69 7.07 144.5 179.5 (2 pole) (3 pole) (4 pole) FD200J3 0.79 20 0.28 DIA. 7 9.88 251 4.06 103 5.43 0.28 138 ...

Page 25

... Approximate Dimensions for Fusible Disconnect Switches FD400J3 – FD800J3 FD400J3 0.91 23 0.28 DIA. 7 12.20 310 4.06 103 0.28 7 FD600J3 & FD800L3 1.42 36 0.35 DIA. 9 14.49 368 3.74 95 0.96 24.5 11.26 (2 pole) Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 26

... Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com BDTL26 — for use with 400A switches 3.19 81 0.53 13.5 1.12 28.5 BDTL27 — for use with 600A switches 0.125 3.1 3.19 0.26 81 6.5 0.53 13 ...

Page 27

Approximate Dimensions for 30A Conversion Mechanisms 6 pole — BDZW5 3 pole transfer switch — BDZW30 Mechanical interlock — BDZW4 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● ...

Page 28

Approximate Dimensions for 60A – 100A Conversion Mechanisms pole — BDZW2 Transfer switch — BDZW1 2. Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ...

Page 29

Approximate Dimensions for 200A – 800A Conversion Mechanisms pole — BDZW9 Transfer switch — BDZW12 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Bussmann ...

Page 30

Approximate Dimensions for 200A – 800A Conversion Mechanisms Bypass switch — BDZW13 Mechanical interlock — BDZW3, BDZW14 & BDZW15 28 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● ...

Page 31

... Electrical interlock — • = Available — = Not available UL listed switches are also CSA approved. For complete technical information please see page 58 & 59. 1000V, IEC 408. Switch only Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 32

... Electrical interlock S = Standard feature • = Available — = Not available UL listed switches are also CSA approved. For complete technical information please see page 58 & 59. 1000V, IEC 408. Switch only 30 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 33

... CDNF100 CDH1S CDH15S CDH6S CDS_S Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com CDNF63 + 16 – 100 Amp switches, 600V, 3 pole UL IEC general AC21 Maximum horsepower rating purpose amp Single phase ...

Page 34

... Handles & Shafts for 16A – 100A Non-Fusible Disconnect Switches Base & DIN Rail Mounted Pistol handles — for use with shafts BDH104, 6 1,3R,12,4,4X 1,3R,12,4,4X Shafts — for use with pistol handles BDH105 CDS_P CDS_T Twisted shafts — Rotates handle 45° ...

Page 35

... Accessories for 16A – 100A Non-Fusible Disconnect Switches Base & DIN Rail Mounted Base and DIN rail mounted switches CDAUX__ CDAUX11 CD_32P CD_63P CD_125P Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 36

... Accessories for 16A – 100A Non-Fusible Disconnect Switches Base & DIN Rail Mounted Terminal shrouds* — snap on mounting for line or load side CDTS__T3 CDTS__T1 * All disconnects are IP20 touch safe as standard. Terminal shrouds provide an additional level of protection. Padlocking adapter CDSA1 CDSA2 ...

Page 37

... CDZW24 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Conversion mechanisms • For use with Base and DIN rail mounted switches only • Switches are not included Description For use on: ...

Page 38

... A snap on fourth pole may be added CDH14S Door mounted switches do not require shafts. CDNF16, 25, 32, 45 & 63 door mounted switches will not accept pistol handles. CDNF45 & 63 door mounted switches can only use screw mounted handles. 36 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 39

... Accessories for 16A – 100A Non-Fusible Disconnect Switches Door Mounted Door mounted switches CDAUX__ CDAUX11 CD_32D CD_63D Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Auxiliary contacts — snap-on mounting ...

Page 40

... Accessories for 16A – 100A Non-Fusible Disconnect Switches Door Mounted Terminal shrouds* — snap-on mounting for line or load side CDTS_T3 CDTS_T1 * All disconnects are IP20 touch safe as standard. Terminal shrouds provide an additional level of protection. Legend plates for selector handles Blank plate ...

Page 41

... BDH60 BDH61 BDS__ BDST__ Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com CDNF160 125 Amp Base & DIN rail mounted switches , 600V UL IEC Maximum horsepower rating general AC21 Three phase ...

Page 42

... Accessories for 125A Non-Fusible Disconnect Switches Auxiliary contacts, top mounted • Accepts four contacts maximum, mounting base always required Mounting base – required for CDAUX_ CDAUXCA10 CDAUXCA01 Auxiliary contacts, side mounted • Accepts four contacts maximum Mounting base, required for CDAUX16011 Max ...

Page 43

... CDMC2 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Conversion mechanisms • For use with Base and Din rail mounted switches only • Switches are not included Description For use on: ...

Page 44

... Accessories for Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 175 – 200 Amp switches, 600V 2 pole 3 pole BDNF175A 4 pole Pistol handles — for use with shafts BDH108 1,3R,4,4X,12 1,3R,4,4X,12 BDH109 Shafts — ...

Page 45

... Accessories for 175A – 200A Non-Fusible Disconnect Switches BDTL25 BDTL175 BDAUX12, 13 BDZX129 BDTS2 BDZX131 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Terminal lug kits Wire For use on: #6 – 300 kcmil BDNF175A & ...

Page 46

... Accessories for 175A – 200A Non-Fusible Disconnect Switches Locking accessories CDETL-ZW16 (U = coil voltage nominal voltage) - Coil voltage CDETL-ZT 80A CDETL-ZT140 Shaft extension coupler BDZW95 Shaft adapter CDZT123 CDETL-ZT140 mounting bracket required. 44 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 47

... Equipment required for a complete installation: • One conversion mechanism • Three disconnect switches Mechanical interlock — BDZW19 Mechanical interlock mechanism prevents both switches from being in the ON position at the same time. Equipment required for a complete installation: • One conversion mechanism • Two disconnect switches • ...

Page 48

... Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 400 – 800 Amp switches, 600V purpose amp rating 2 pole BDNF600A 3 pole 4 pole Pistol handles — for use with shafts BDNF800A 1,3R,4,4X,12 ...

Page 49

... Accessories for 400A – 800A Non-Fusible Disconnect Switches BDTL26 BDTL27 BDTL30 BDTL175/400 BDTL32 BDAUX1–6 BDZX85 BDTS__ BDZX71 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Terminal lug kits Wire ...

Page 50

... Accessories for 400A – 800A Non-Fusible Disconnect Switches 90° angle kit BDZX108 Shaft extension coupler BDZW95 Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and Ronis interlock. For adapting to the interlock system Electrical interlock principle for interlocking the switch movement ...

Page 51

... One conversion mechanism • Three disconnect switches Mechanical interlock — BDZW3, BDZW14, BDZW15 Mechanical interlock mechanism prevents both switches from being in the ON position at the same time. Equipment required for a complete installation: • One conversion mechanism • Two disconnect switches • Two shafts • ...

Page 52

... The US National Electric Code does not specify HP – 3150 — — — ratings for switches this large. Please select a switch based on 115% of application FLA. For example: a 1200 1600 motor with an FLA of 800A would require a 1200A 1600 2500 switch: 800A x 115% = 920A, the closest higher rated ...

Page 53

... Accessories for 1200A – 3150A Non-Fusible Disconnect Switches BDS__45 BDTL28 BDTL28/2 BDBUS115 BDBUS114 BDAUX1 BDAUX1 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Twisted shafts – Rotates handle 45° .47 x .47" ...

Page 54

... Accessories for 1200A – 3150A Non-Fusible Disconnect Switches Handle support bracket BDZX71 90° angle kit BDZX90 Shaft extension coupler BDZW95 Locking accessories CDETL-ZW5 = Coil voltage CDETL-ZT80 52 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 55

... Equipment required for a complete installation: • One conversion mechanism • Three disconnect switches Mechanical interlock —BDZW15 Mechanical interlock mechanism prevents both switches from being in the "ON" posi- tion at the same time. Handles are not included. Equipment required for a complete installation: • One conversion mechanism • ...

Page 56

... BDFLNF30-S BDFLNF60-S BDFLNF100-S BDFLNF175-S BDTL24 BDTL25 BDFLNF200A-S BDFLNF400-S BDFLNF600A-S Side operated switches available through 800A as IEC rated. BDTL26 BDTL27 54 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com BDFLNF200A pole — ...

Page 57

... Flange Operated Non-Fusible Disconnect Switches 30A – 200A For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit BDFHNHS12 BDFHS12 BDTL24 BDTL25 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 58

... Wire tightening lb. in Wire range AWG #18 – Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 – 0. FLA. 56 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com UL & CSA ...

Page 59

... Wire tightening lb. in Wire range AWG UL Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 – 0. FLA. Multi-tap lug available. IEC rated only. Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com UL & ...

Page 60

... IEC Technical Data for Non-Fusible Disconnect Switches CDNF16 – CDNF160 Catalog number 3 pole CDNF16 Rated insulation and operation 40°C voltage, AC20 and DC20 V 750 Rated impulse withstand voltage kV Rated thermal current 20/DC 20 open A 40°C enclosed A 60°C enclosed A Rated operational currents ...

Page 61

... IEC Technical Data for Non-Fusible Disconnect Switches BDNF175 – BDNF3150 Catalog number 3 pole Rated insulation and operational 40°C voltage, AC20 and DC20 V 1000 Rated impulse withstand voltage kV Rated thermal current, Ith AC 20/DC 20 open A 40°C enclosed A 60°C enclosed A Rated operational currents ...

Page 62

... Weight 3 pole kg 4 pole kg Dimension 3 pole Power loss per pole W Shaft size — square Switch operating torque for rotary 3 pole switches Nm Suitable conductor cross section 0.75 – 10 Bolt size Auxiliary contacts CDAUX_ _ Ratings according to IEC 9-47-5-1 Rated voltage, U VAC i Thermal current ...

Page 63

... Dimension 3 pole H mm 212 Power loss per one pole W Shaft size — square mm Switch operating torque for rotary 3 pole switches Nm 2 Suitable conductor cross section Cu mm Bolt size Auxiliary contacts Ratings according to IEC 947-5-1 Rated voltage, U VAC i Thermal rated current, I ...

Page 64

... Approximate Dimensions for Non-Fusible Disconnect Switches CDNF16 — CDNF100 CDNF16, CDNF25, CDNF32 — base & DIN rail mounted switch 0.43 0.43 0. DIA. 4.5 0.47 12 2.13 54 0.87 22 0.43 1. CDNF45, CDNF63 — base & DIN rail mounted switch 0.69 0.69 17.5 17.5 0.18 DIA ...

Page 65

... Approximate Dimensions for Non-Fusible Disconnect Switches CDNF16D — CDNF100D CDNF16D, CDNF25D, CDNF32D — door mounted switch 0.08 2 0.88 22 MOUNTING HOLE DETAIL CDNF45D, CDNF63D — door mounted switch 1.89 48 1.42 36 0. MOUNTING HOLE DETAIL CDNF30D, CDNF60D, CDNF100D — door mounted switch 2 ...

Page 66

... Approximate Dimensions for Non-Fusible Disconnect Switches CDNF175A — BDNF200A CDNF175A 8.39 213 2.91 74 0.06 1.5 4.33 110 (2 Pole) 5.91 150 (2 Pole) BDNF200A 8.39 213 2.91 74 0.06 1.5 4.72 120 (2 Pole) (3 Pole) 6.30 8.50 160 216 (2 Pole) (3 Pole) 64 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 67

... Approximate Dimensions for Non-Fusible Disconnect Switches BDNF400 1.54 39 0.28 DIA. 7 12.05 306 4.06 103 0.28 7 7.48 190 (2 Pole) BDNF600A 1.65 42 0.28 DIA. 7 11.93 303 4.06 103 0.31 8 1.93 49 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 1 ...

Page 68

... Approximate Dimensions for Non-Fusible Disconnect Switches BDNF800A — BDNF1200 BDNF800A 1.10 28 0.35 DIA. 9 19.21 488 3.74 95 0.94 24 2.07 52.5 10.71 (2 Pole) BDNF1200 1.10 28 0.35 DIA. 9 19.21 488 3. Pole) 66 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 10 ...

Page 69

... Approximate Dimensions for Non-Fusible Disconnect Switches BDNF1600 — BDNF3150 BDNF1600 0.35 DIA. 9 25.28 642 3.74 95 0.94 24 BDNF2000 – BDNF3150 0.35 DIA. 9 25.28 642 3.74 95 0.94 24 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 70

... BDTL30 — for use with 800A switches 1.12 28.5 4.92 125 0.125 3.1 0.26 6.5 0.41 10.3 BDTL28 & BDTL28/2 — for use with 1200A – 3150A switches 1.56 39.5 4.92 125 0.13 3.3 0.43 11 0.41 10.3 Bussmann 2.40 1 ...

Page 71

... Fusible switches are UL listed to the UL98 standard. 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 72

... Pistol 1,3R,4,4X,12 Fusible switches are UL listed to the UL98 standard. 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." 70 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 73

... Other Configurations for Enclosed Fusible Disconnect Switches 30A – 800A UL general purpose Type of Switch amp rating 4 Pole 6 Pole 30 (J fuses) Transfer Bypass Mech. interlock 4 Pole 6 Pole 30 (CC fuses) Transfer Bypass Mech. interlock 4 Pole 60 6 Pole Transfer Mech. interlock 2 Pole 100 ...

Page 74

... Other Configurations for Enclosed Fusible Disconnect Switches 30A – 800A UL General purpose Type of Switch amp rating 4 Pole 6 Pole 30 (J fuses) Transfer Bypass Mech. interlock 4 Pole 6 Pole 30 (CC fuses) Transfer Bypass Mech. interlock 4 Pole 60 6 Pole Transfer Mech. interlock 2 Pole 100 ...

Page 75

... Start/stop pushbuttons 2 position selector switch 30A – 3000A 3 position selector switch Pilot light "red/run" Ammeter 1 phase Voltmeter Ground lugs All enclosed switches are provided with a standard integral ground lug. Ground lug Switch size 30 ( #14 – 1/0 100 – 400 #6 – 250 600 – ...

Page 76

... Mechanical interlock mechanism prevents both switches from being in the ON position at the same time. Transfer and bypass enclosed switches include the load side bussed or cabled together, and all switches come standard with ground lugs. = Three poles 74 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Bussmann ® ...

Page 77

... Pole Enclosed Non-Fusible Switches 16A – 100A Type 1 — & 4 Pole non-fusible switches Type 3R Stainless, 12 — & 4 Pole non-fusible switches Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Amps ...

Page 78

... Approximate Dimensions for 2, 3 & 4 Pole Enclosed Non-Fusible & Fusible Switches 16A – 3150A NF; 30A – 800A F Non-fusible switches Amp Enclosure A B rating type Height Width 1 6.0 6.0 3R 6.0 6.0 4 6.0 6.0 ENF16,25, 6.0 6.0 4X Plastic 6.0 6.0 12 6.0 6.0 IP65 (A) 4 ...

Page 79

... Enclosure depth only. Handle is not included. Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 6 Pole, transfer & mechanical interlock fusible switches Weight Amp Enclosure Width Depth ...

Page 80

... Enclosure depth only. Handle is not included. Uses a type 4 enclosure, less cost. 78 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Bypass mechanism for fusible switches Weight Amp Enclosure Depth ...

Page 81

... Enclosed Non-Fusible Disconnect Switches 16A – 3150A 3 Pole, 600V, 16A – 100A — Selector handle UL general purpose amp rating Pole, 600V, 16A – 3150A — Pistol handle UL general purpose amp rating 100 125 200 400 600 800 1200 1600 2000 3150 Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12 ...

Page 82

... NOTE: All enclosed switches are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired. Please substitute the handle suffix code (2nd and 3rd from last characters) with the red/yellow handle catalog number suffix from page 3.12. There is no additional price adder for changing to a red/yellow handle of equal ratings and style. EXAMPLE: A red/yellow selector handle for an NF161-3PBJA can be substituted for the black selector handle by using the " ...

Page 83

... Enclosed Non-Fusible Disconnect Switches 16A – 400A Other Configurations UL General purpose Type of switch amp rating 4 Pole 6 Pole 16 Transfer Bypass Mech. interlock 4 Pole 6 Pole 25 Transfer Bypass Mech. interlock 4 Pole 6 Pole 40 Transfer Bypass Mech. interlock 4 Pole 60 6 Pole Transfer Bypass Mech. interlock ...

Page 84

... Enclosed Non-Fusible Disconnect Switches 16A – 400A Other Configurations UL General purpose Type of switch amp rating 4 pole 16 6 pole Transfer Bypass Mech. interlock 4 pole 25 6 pole Transfer Bypass Mech. interlock 4 Pole 6 Pole 40 Transfer Bypass Mech. interlock 4 Pole 60 6 Pole Transfer Bypass Mech ...

Page 85

... Enclosed Non-Fusible Disconnect Switches 600A – 3150A Other Configurations UL General purpose Type of switch amp rating 2 Pole 4 Pole 600 6 Pole Transfer Bypass Mech. interlock 2 Pole 4 Pole 800 6 Pole ransfer Bypass Mech. interlock 2 Pole 4 Pole 1200 6 Pole Transfer Bypass Mech. interlock 2 Pole ...

Page 86

... Enclosed Non-Fusible Disconnect Switches 600A – 3150A Other Configurations UL General purpose Type of switch amp rating 2 pole 4 pole 600 6 pole Transfer Bypass Mech. interlock 2 pole 4 pole 800 6 pole Transfer Bypass Mech. interlock 2 pole 4 pole 1200 6 pole Transfer Bypass Mech. interlock 2 pole ...

Page 87

... Pilot light “red/run” Ammeter 1 phase Voltmeter Ground lugs All enclosed switches are provided with a standard integral ground lug. Ground lug Switch size 16A – 100A 200A – 400A #6 – 250 mcm 600A – 1200A #2 – ...

Page 88

... Technical Data for Enclosed Non-Fusible Disconnect Switches Switch ratings, 16 – 3150 Amps, 600V UL General Single phase purpose amp rating 120V 200V 240V 16 1/2 1.5 1 7.5 7.5 100 125 7 200 –– –– –– 400 –– –– ...

Page 89

... NEMA Environmental Ratings for Enclosed Disconnect Switches Introduction An enclosure is a surrounding case constructed to provide a degree of protection to personnel against accidental contact with the enclosed equipment and to provide a degree of protection to the enclosed equipment against specified environmental conditions. A brief description of the more common types of enclosures used by the electrical industry relating to their environmental capabilities follows. Refer to Defi ...

Page 90

... CFD30CC3S 5 CDNF160 29, 39, 56, 58, 60 CFD30CC4 5 CDNF160-2 39 CFD30J3 CDNF160D 39 CFD30J3F CDNF16D 36, 63 CFD30J3S CDNF175A 64 CFD30J4 CDNF25 29, 31, 56, 58, 60, 62 CFD60J3 CDNF25D 36, 63 CFD60J3F CDNF30 29, 31, 56, 58, 60, 62 CFD60J3S CDNF30D 36, 63 CFD60J4 CDNF32 29, 31, 56, 58, 60, 62 CFDAUX01 CDNF32D 36, 63 CFDZX171 ...

Page 91

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...

Page 92

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com ...