13. Packing form
14. Reliability test items
【Result evaluation criteria】
No
1
2
3
4
5
6
7
8
9
Under the display quality test conditions with normal operation state, these shall be no change which may affect
practical display function.
n) When handling LCD modules and assembling them into cabinets, please be noted that long-term storage in
o) Blow off dust with N
p) Please connect from the product side to the inverter's power source ground line, as the PWB's ground for
a) Piling number of cartons: 3(maximum)
b) Packing quantity in one carton : 10
c) Carton size : 706mm(W) × 532mm(D) × 421mm(H)
d) Total mass of one carton filled with full modules : 25.5Kg
High temperature storage test
Test item
Low temperature storage test
High temperature
& high humidity operation test
High temperature operation test
Low temperature operation test
Vibration test
(non- operating)
Shock test
(non- operating)
Thermal shock test
(non- operating )
ESD test
the environment of oxidization or deoxidization gas and the use of such materials as reagent, solvent,
adhesive, resin, etc. which generate these gasses, may cause corrosion and discoloration of the LCD
modules.
is recommended.
inverter is not connected to module's bezel.
2
blower for which static electricity preventive measure has been taken. Ionized air gun
Waveform : Sine wave
Frequency : 10∼57Hz/Vibration width (one side) : 0.075mm
Conditions
Ta = 60℃
Ta = -25℃
Ta = 50℃
Ta = 0℃
Sweep time : 11minutes
Test period : 3 hours
Max. gravity : 490m/s
Pulse width : 11ms, sine wave
Direction : ±X, ±Y, ±Z,
Ta=-25℃∼60℃ ; 5 cycles
Test period : 10 hours (1 hour for each temperature)
Ta = 40℃ ; 95%RH 240h
(No condensation)
(The panel temperature must be less than 60℃)
Contact discharge method : C=150pF,R=330Ω
Air discharge method : C=150pF,R=330Ω
(non- operating) Pass +/- 15kV
(operating)
(non- operating) Pass +/- 20kV
(operating)
: 57∼500Hz/Gravity : 9.8m/s
once for each direction.
(1 hour for each direction of X,Y,Z)
240h
240h
240h
240H
Pass +/- 8kV
2
Pass +/- 10kV
2
LD − 17221 − 14