SIP43101DLP-T1 Vishay, SIP43101DLP-T1 Datasheet - Page 5

no-image

SIP43101DLP-T1

Manufacturer Part Number
SIP43101DLP-T1
Description
Manufacturer
Vishay
Datasheet

Specifications of SIP43101DLP-T1

Switch Type
High Side/Low Side
Power Switch Family
SiP43101
Output Current
200mA
Number Of Outputs
Dual
Mounting
Surface Mount
Supply Current
6mA
Package Type
PowerPAK MLP44
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Pin Count
16
Power Dissipation
850W
Lead Free Status / Rohs Status
Not Compliant
Turn On Delay
The turn on delay prohibits the output switches from being
turned on for a period of time after V
8 V and the undervoltage condition no longer exists. The
UVLO function keeps the external C
until V
current source charges the capacitor from GND to 4.7 V. A
comparator detects when the voltage on C
through 4 V and enables the output switches. The delay time
is a function of the capacitor value and is defined as
1.6 ms/nF.
An external switch can be connected across the capacitor to
disable the output switches and reset the time delay.
Vishay Siliconix maintains worldwide manufacturing capability. Products may be manufactured at one of several qualified locations. Reliability data for Silicon Technology and
Package Reliability represent a composite of all qualified locations.
http://www.vishay.com/ppg?72640.
Document Number: 72640
S-51493, Rev. D—15-Aug-05
CC
is greater than 8 V. Subsequently, an internal 2.5-mA
FAULT
C
IN
IN
GND
V
DEL
IN
CC
2B
2A
1
DEL
CC
capacitor discharged
has passed through
Thermal Shut Down
DEL
Short Citcuit
UVLO
Reset
passes
For related documents such as package/tape drawings, part marking, and reliability data, see
Reference
Short Circuit and Overcurrent indication
When an overcurrent or short circuit condition occurs on
either switch, the SiP43101 enters a hiccup current limiting
mode. In this mode, the capacitor on C
down to 3 V, thus turning off the output switches, and then is
charged up to 4 V by a 2.5-mA internal current source, thus
turning the switches on again. If the overcurrent or short circuit
condition remains this cycle will continue. The switches are
enabled at a very low duty cycle, minimizing the power
dissipation and protecting the switches from damage.
The FAULT output will switch to GND, indicating that an
overload condition or short circuit condition exists.
Control
Logic
Vishay Siliconix
DEL
SiP43101
is discharged
www.vishay.com
C
E
C
E
2
1
2
1
5

Related parts for SIP43101DLP-T1