D4A2501N Omron, D4A2501N Datasheet
D4A2501N
Specifications of D4A2501N
Related parts for D4A2501N
D4A2501N Summary of contents
Page 1
... Be sure to read Safety Precautions on page and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) D4A-@@@@N (Set model number) (1) (2) (3) (1) Receptacle box 1 : 1/2-14 NPT conduit (SPDT, double-break) ...
Page 2
... Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-3101N becomes D4A-3101N-F.) Ask your nearest OMRON representative for details. *1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page 12). ...
Page 3
... Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest OMRON representative about delivery times and prices. ...
Page 4
... D4A-0007-HN Side adjustable D4A-0008N *1. Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on page 12). *2. The D4A-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result. ...
Page 5
... Note: Refer to page 12 for Lever shapes and applicable models. Specifications Approved Standards Agency Standard UL UL508 CSA CSA C22.2 No.14 CCC (CQC) GB14048.5 Note: Ask your OMRON representative for information on approved models. Ratings Non-inductive load (A) Rated Resistive Type Lamp load voltage load NC NO ...
Page 6
... Note: The above figures are initial values. *1. Excluding maintained models. *2. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *3. 1,500 VAC is applied to the indicator lamp type. ...
Page 7
... Switching current (A) Structure and Nomenclature Structure (DPDT Double-break) Head With the Roller Lever and Side Plunger Switches, the direction of the switch head can be varied to any of the four directions by loosing the roller lever switch screws at the four corners of the head. The Roller Lever Switch ...
Page 8
... Contact form Lamp unit internal ---- circuit * Switches with indicators are factory-set to light when the switch is not operated, but the setting can be changed to light for operation (dotted lines). Contact model With neon lamp indicator * With LED indicator D4A-0300N D4A-0E00N Lamp unit ...
Page 9
... Dimensions and Operating Characteristics Set Model Numbers Roller Lever Switches Note: Levers of the side rotary type are optionally available. Standard D4A-3@01N, D4A-4@01N High-sensitivity D4A-3@02N, D4A-4@02N Low-torque D4A-3@03N, D4A-4@03N High-sensitivity/Low-torque D4A-3@04N, D4A-4@04N Sequential Operation D4A-4@17N Center Neutral Operating D4A-4@18N Maintained D4A-3 05N, D4A-4 ...
Page 10
... Operating force OF max. 19.61 N Release force RF min. 4.90 N Pretravel PT max. 2.4 mm Overtravel OT min. 5.1 mm Movement Differential 0 max 34±0.8 mm 44±0 Operating position Top Plunger Switches Standard Stainless steel plunger 10 dia. PT D4A-3 @ 09N Four, M4 (length: 12) D4A-4 @ 09N screws for head 27 OP +0.2 5.2 dia. 0 ...
Page 11
Flexible Rod Spring wire (see note 1) D4A-3 12N @ D4A-4 @ 12N PT (see note 2) (287) Four, M4 (length: 12) screws for head 330 88 27 +0.2 5.2 dia. 0 mounting holes R2.6 70.5 59.5±0.2 6 0.8 R2.6 ...
Page 12
... Levers (for Roller Lever Switches) Note: No D4A-0003N or D4A-0004N head should be used with the adjustable roller lever or mechanical malfunctioning could result because the total weight of the adjustable roller lever is comparatively large. Use a standard-load head (D4A-0001N or D4A-0002N) instead. Roller Lever D4A-A00 11.5 19 dia. ...
Page 13
Head and Lever Positions • The operating head can be positioned and locked in any of four 90° positions and a lever can lock in any position through 360° around the shaft of the Limit Switch. Furthermore, the lever can ...
Page 14
... Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. ...
Page 15
... Connectors To satisfy IP67, apply sealing tape to the connector conduit. Appropriate external diameter of cables is 5 dia. Use OMRON’s SC-@M Series. Tighten the Connectors to a torque of 1.8 to 2.2 N·m. Maintenance and Repair The user must not maintain or repair equipment incorporating any D4A-N model ...
Page 16
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...