208470-3 TE Connectivity, 208470-3 Datasheet - Page 6

CIR CONN PLUG SIZE 28 37POS FREE HANGING

208470-3

Manufacturer Part Number
208470-3
Description
CIR CONN PLUG SIZE 28 37POS FREE HANGING
Manufacturer
TE Connectivity
Series
Series 1r
Datasheets

Specifications of 208470-3

Connector Type
Circular Industrial
Connector Body Material
Thermoplastic
Gender
Receptacle
Connector Mounting
Free Hanging
Connector Shell Size
28
Rohs Compliant
Yes
Mount
Free Hanging
Mount Angle
Straight
Shell Size
28
Shell Type
Metal
Product Series
Series 1
Thread Size
1-7/16 - 18 UNEF-2A
Sealed
Yes
Mating Retention Type
Threaded Coupling
Vde Tested
No
Seal Type
Tetraseal
Number Of Positions
37
Number Of Signal Positions
37
Contact Type
Socket
Reverse Gender
Standard
Connector Style
Plug
Mating Alignment Type
Keyed
Housing Material
Thermoplastic - GF
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Environmental Protection
With
Reverse Numbering
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Fluid Resistance
Immersion
Accepts Wire Insulation Diameter, Range (mm [in])
2.54 [0.100]
4.2.
4.3.
4.4.
4.5.
Rev A
Retention of Qualification
If, in a five-year period, no changes to the product or process occur, the product shall be subjected to
the groups of the testing described in the test sequence, see Figure 3. Justification for exceeding this
time limit must be documented and approved by the division manager.
Requalification Testing
If changes significantly affecting form, fit, or function are made to the product or to the manufacturing
process, product assurance shall coordinate requalification testing, consisting of all or part of the
original testing sequence as determined by development/product, quality, and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup, or operator deficiencies shall not disqualify the product. When
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
Testing to confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Contacts
Type XII
Contact
Size
20
16
8
Wire
Size
20
22
24
26
28
14
16
18
20
22
24
26
28
30
10
12
14
16
8
Figure 5
Amperes
Current
Termination Resistance
Test
7.5
5.0
3.0
2.0
1.5
7.5
5.0
3.0
2.0
1.5
1.2
17
13
10
35
33
23
17
13
Resistance,
maximum
Milliohms
10.0
12.0
15.0
21.0
32.5
14.5
19.0
30.0
43.0
1.25
1.50
2.70
6.0
6.5
7.5
9.0
9.5
.80
.95
108-10040
6 of 7