ACPL-P341-000E Avago Technologies US Inc., ACPL-P341-000E Datasheet - Page 8

no-image

ACPL-P341-000E

Manufacturer Part Number
ACPL-P341-000E
Description
Gate Drive Optocoupler,LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-P341-000E

No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
16mA
Opto Case Style
SOIC
No. Of Pins
6
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
Yes
Lead Free Status / Rohs Status
 Details
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Maximum pulse width = 1 ms.
11. Pulse Width Distortion (PWD) is defi ned as |t
12. The diff erence between t
13. Pin 2 needs to be connected to LED common.
14. Common mode transient immunity in the high state is the maximum tolerable dV
15. Common mode transient immunity in a low state is the maximum tolerable dV
16. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≤ 4500 V
17. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≤ 6000 V
18. Device considered a two-terminal device: pins 1, 2, and 3 shorted together and pins 4, 5 and 6 shorted together.
19. The device was mounted on a high conductivity test board as per JEDEC 51-7.
8
Derate linearly above 70° C free-air temperature at a rate of 0.3 mA/°C.
Maximum pulse width = 10 s. This value is intended to allow for component tolerances for designs with I
section for additional details on limiting I
Derate linearly above 85° C free-air temperature at a rate of 16.9 mW/°C.
Derate linearly above 85° C free-air temperature at a rate of 15.3 mW/°C. The maximum LED junction temperature should not exceed 125° C.
Maximum pulse width = 50 s.
Output is sourced at -2.5 A with a maximum pulse width = 10 s. V
Output is sourced at 2.5 A with a maximum pulse width = 10 s. V
Output is sourced at -2.5 A/2.5 A with a maximum pulse width = 10 s.
In this test V
output will remain in the high state (i.e., V
will remain in a low state (i.e., V
current limit, I
current limit, I
OH
I-O
I-O
is measured with a dc load current. When driving capacitive loads, V
< 5 A).
< 5 A).
PHL
and t
O
< 1.0 V).
PLH
between any two ACPL-P341 parts under the same test condition.
OH
O
> 15.0 V).
peak.
PHL
-t
PLH
| for any given device.
O
CC
-V
-V
EE
O
is measured to ensure 15 V or below.
is measured to ensure 15 V or below.
CM
/dt of the common mode pulse, V
OH
CM
will approach V
/dt of the common mode pulse, V
CC
O
as I
peak minimum = 2.5 A. See applications
OH
RMS
RMS
approaches zero amps.
for 1 second (leakage detection
for 1 second (leakage detection
CM
, to assure that the output
CM
, to assure that the

Related parts for ACPL-P341-000E