19.91.9.012.4000 FINDER, 19.91.9.012.4000 Datasheet

no-image

19.91.9.012.4000

Manufacturer Part Number
19.91.9.012.4000
Description
RELAY, POWER MODULE, 1CO, 10A
Manufacturer
FINDER
Datasheet

Specifications of 19.91.9.012.4000

Ip/nema Rating
20
Supply Voltage
12VDC
Contact Configuration
1 CO
Contact Current Max
16A
Contact Rating
250V Ac
External Depth
60.8mm
External Length / Height
88.8mm
External Width
17.5mm
No.
RoHS Compliant
Svhc
No SVHC (20-Jun-2011)
Rohs Compliant
Yes
Features
Auto/Off/On output module 10 A
Application examples:
Wiring diagram
For outline drawing see page 11
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltageV AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1 (24/110/220 V)
Minimum switching load
Standard contact material
Feedback contact specification (terminals B1-B2)
Contact configuration
Maximum current
Rated voltage
Supply & Input specification
Nominal voltage (U
Rated power
Operating range
Technical data
Ambient temperature range
Protection category
Approvals (according to type)
Auto/Off/On output module intended to
permit the automatic control of pumps, blowers
or motor groups. Or, in the case of installation,
maintenance or failure, to permit the load
equipment to be turned “Off“ or controlled
under “On“ control
Ideal interface for PLC and electronic systems
Only 11.2 mm wide
3 function selector switch:
- Auto: works as a monostable relay
- Off: relay permanently OFF
- On: relay permanently ON
24V AC/DC supply and module input
35 mm rail (EN 60715) mounting
control of pumps, blowers or motor groups
primarily suited to Industrial control systems
Controller, PLC
(following A3 input)
N
)
V AC (50/60 Hz)
Type 19.21
VA (50 Hz)/W
mW (V/mA)
V AC/DC
V DC
kW
mA
AC
DC
VA
VA
°C
A
A
19 Series - Override & Status indicating modules
B1-B2 feed back information to the controller for Auto-operation
A3-A2 From the controller requested operation
Switch position:
Auto-Operation
Request
1 CO output contact
11.2 mm wide
Feedback contact
19.21.0.024.0000
1 NO (SPST-NO)
0.6 (50 Hz)/0.4
(0.8...1.1) U
(0.8...1.1) U
10/0.3/0.12
(0.8…1.1)U
1 CO (SPDT)
300 (5/5)
250/400
–20…+50
Response
AgSnO
10/15
2,500
1,000
IP 20
0.44
500
0.3
24
24
24
2
Intervention-(Manual-)Operation
N
N
N
LED Signals
1

Related parts for 19.91.9.012.4000

19.91.9.012.4000 Summary of contents

Page 1

Features Auto/Off/On output module 10 A Auto/Off/On output module intended to • permit the automatic control of pumps, blowers or motor groups. Or, in the case of installation, maintenance or failure, to permit the load equipment to be turned “Off“ ...

Page 2

Features 1-channel status indicating module 1-channel indicating module to provide visual • indication of BMS/DDC/PLC input or output status with immediate indication of its importance or urgency according to the colour of the LED. A change-over output contact, following the ...

Page 3

Features 2-channel status indicating module 2-channel indicating module to provide visual • indication of BMS/DDC/PLC input or output status with immediate indication of its importance or urgency according to the colour of the LED. Two NO output contacts, following the ...

Page 4

Features Override module - Auto/Off/Hand Auto/Off/Hand override module intended to • permit the automatic control of pumps, blowers or motor groups. Or, in the case of installation, maintenance or failure, to permit the load equipment to be turned “Off“ or ...

Page 5

Features Override module - Auto/Off/Low/High Override output module intended to permit the • automatic control of two-speed pumps, blowers or motor groups. Or, in the case of installation, maintenance or failure, to permit the load equipment to be turned “Off“ ...

Page 6

Features Analogue override module - Auto/Hand (0…10)V Analogue output module intended to provide, • by the selection switch on the front panel, a (0…10) V output, automatically or by hand. With the selector switch in position “A“ (Automatic) the (0…10) ...

Page 7

Features Power relay module 16 A Suitable for Lamps load • AgSnO contacts for heavy duty, high inrush • 2 current loads DC supply ( • LED indicator • Reinforced insulation between supply and • contacts Cadmium ...

Page 8

... Contact material 0= Standard for 19.21/31/32/41/42/50 4= Standard for 19.91 Codes / Module width 19.21.0.024.0000 / 11.2 mm 19.31.0.024.0000 / 17.5 mm 19.32.0.024.0000 / 17.5 mm 19.41.0.024.0000 / 17.5 mm 19.42.0.024.0000 / 35.0 mm 19.50.0.024.0000 / 17.5 mm 19.91.9.012.4000 / 17.5 mm 19.91.9.024.4000 / 17.5 mm 19.31/32 19.41/42 19.50 1,000 2,000 — 750 1,000 — — 1,500 1,500 19.21/31/32/42/ V/m ...

Page 9

Wiring diagrams - Application examples Type 19.21 Controller, PLC Type 19.21 Type 19.31 * LED Controller, PLC Type 19. can be, for example, a NO-contact with the purpose of indicating “in operation” (selecting green as LED color) or ...

Page 10

Wiring diagrams - Application examples Type 19.41 Controller, PLC Type 19.41 Type 19.42 Controller, PLC Type 19.42 Type 19.50 Input analog signal Controller, PLC Type 19.50 In the selector position A (Automatic) the 0...10 V set point of Yin - ...

Page 11

Type 19.21 Screw terminal Type 19.41 Screw terminal Type 19.50 Screw terminal 19 Series - Override & Status indicating modules Outline drawings Type 19.31-19.32 Screw terminal Type 19.42 Screw terminal Type 19.91 Screw terminal 11 ...

Page 12

Accessories Sheet of marker tags, for 19.21 type, plastic, 40 tags, 8x10 mm 019.40 Sheet of marker tags, for 19.31/32/41/42/50/91 types, plastic, 72 tags, 6x12 mm 060.72 Identification tag, for 19.31/32/41/42/50 types, plastic, 1 tag, 17x25.5 mm 019.01 Adaptor for ...

Page 13

Application notes Intervention Modules The demand for security apparatus, heating, air conditioning or efficient energy use in offices, hotels, and private homes or in industrial space is growing constantly, leading to the installation of increasingly complex electronic systems. But what ...

Page 14

...

Related keywords