R4H3030FCC EATON CUTLER HAMMER, R4H3030FCC Datasheet - Page 14

no-image

R4H3030FCC

Manufacturer Part Number
R4H3030FCC
Description
H-FRAME, CC FUSIBLE ROTARY DISC, 3P, 600V, 30A
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of R4H3030FCC

No. Of Poles
3
Contact Current Ac Max
30A
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Switching Devices
R5 Series (UL 508) Non-Fusible 16–80A
Technical Data and Specifications
UL 508 (CSA 22.2 No. 14) Manual Motor Controller “Suitable as Motor Disconnect” from 16–80A
Technical Characteristics
Approvals
Short-circuit rating at 600 Vac (kA)
Branch circuit fuse type
Maximum fuse rating
Maximum UL Horsepower Ratings/Maximum Motor FLA Current, Three-Phase
208 Vac
220–240 Vac
440–480 Vac
600 Vac
Connection
Wire range (AWG), solid, single cable
Wire range (AWG), solid, two cables
Wire range (AWG), stranded, single cable
Wire range (AWG), stranded, two cables
Mechanical Characteristics
Endurance, number of mechanical cycles
Auxiliary Contacts
Electrical characteristics
IEC 60947-3 Characteristics
Technical Characteristics
Rated Operational Currents I
Rated Voltage
500 Vac
500 Vac
690 Vac
690 Vac
690 Vac
Thermal Current I
Thermal current I
Rated insulation voltage U
Rated impulse withstand voltage U
Operational Power in AC-23 (kW)
At 400 Vac without prebreaking AC in AC-23 (kW)
At 500 Vac without prebreaking AC in AC-23 (kW)
At 690 Vac without prebreaking AC in AC-23 (kW)
Fuse Protected Short-Circuit Withstand (kA rms Prospective)
Prospective short-circuit current (kA rms)
Associated fuse rating (A)
Overload Capacity (U
Rated short-time withstand current 0.3 s. I
Rated short-circuit making capacity Icm (kA peak)
Connection
Minimum Cu cable cross section (mm
Maximum Cu cable section (mm
Tightening torque minimum/maximum (Nm)
Notes
10
Short-circuit rating achieved when used with respective fuse type and maximum fuse rating.
A/B: Category with index A = frequent operation; category with index B = infrequent operation.
The power value is given for information only; the current values vary from one manufacturer to another.
For a rated operating voltage, U
th
(40°C)
th
at 40°C (A)
Switching Devices PG00802002E—November 2010 www.eaton.com
i
(V)
e
415 Vac)
2
)
Load Duty Category
AC-22 A/AC-22 B
AC-23 A/AC-23 B
AC-21 A/AC-21 B
AC-22 A/AC-22 B
AC-23 A/AC-23 B
imp
e
= 400 Vac.
2
e
)
(kV)
(A)
CW
16A
UL 508/CSA 22.2 No. 14
10/65
J
60/30A
3/10.6
5/15
10/14
10/11
#14–#10
2x #12
#14–#4
2x (#14–#12)
A300
10,000
(kA rms)
16A
A/B
16/16
16/16
16/16
16/16
16/16
16
800
8
7.5
7.5
7.5
50
16
2.5
6
1.5
16
2/2.2
25A
UL 508/CSA 22.2 No. 14
10/65
J
60/30A
7.5/24.2
7.5/22
15/21
20/22
#14–#10
2x #12
#14–#4
2x (#14–#12)
10,000
A300
25A
A/B
25/25
25/25
25/25
25/25
25/25
25
800
8
11
11
15
50
25
2.5
6
1.5
16
2/2.2
30A
UL 508/CSA 22.2 No. 14
10/65
J
60/30A
7.5/24.2
7.5/22
15/21
20/22
#14–#10
2x #12
#14–#4
2x (#14–#12)
10,000
A300
32A
A/B
32/32
25/25
32/32
32/32
25/25
32
800
8
15
15
18.5
50
32
2.5
6
1.5
16
2/2.2
40A
UL 508/CSA 22.2 No. 14
10/65
J
60/30A
7.5/24.2
7.5/22
20/27
25/27
#14–#10
2x #12
#14–#4
2x (#14–#12)
10,000
A300
40A
A/B
40/40
25/25
40/40
32/40
25/25
40
800
8
18.5
15
18.5
50
40
2.5
6
1.5
16
2/2.2
60A
UL 508/CSA 22.2 No. 14
50/65
J
100/60A
15/46.2
15/42
30/40
30/32
#14–#10
2x #12
#14–#1
2x (#10–#6)
10,000
A300
63A
A/B
63/63
63/63
63/63
40/63
40/40
63
800
8
30
30
30
50
63
3
9
2.5
35
3.5/3.85
80A
UL 508/CSA 22.2 No. 14
50/65
J
100/60A
15/46.2
20/54
40/52
40/41
#14–#10
2x #12
#14–#1
2x (#10–#6)
10,000
A300
80A
A/B
80/80
63/63
80/80
63/80
40/40
80
800
8
37
37
37
50
80
3
9
2.5
35
3.5/3.85

Related parts for R4H3030FCC