2-1462051-2 TE Connectivity, 2-1462051-2 Datasheet

RF SIGNAL RELAY, SPDT, 24VDC, 2A, PC BOARD

2-1462051-2

Manufacturer Part Number
2-1462051-2
Description
RF SIGNAL RELAY, SPDT, 24VDC, 2A, PC BOARD
Manufacturer
TE Connectivity
Series
HF3S, AXICOMr
Datasheets

Specifications of 2-1462051-2

Coil Type
DC, Monostable
Contact Configuration
SPCO
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
24V
Coil Resistance
4.114kohm
Rohs Compliant
Yes
Relay Type
RF
Contact Form
SPDT (1 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Current
5.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Features
-
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
Silver (Ag), Gold (Au)
Operate Time
5ms
Release Time
5ms
Coil Power
140 mW
Operating Temperature
-55°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
n
n
n
n
n
n
n
Typical applications
Cable modems and linecards/ CATV, Tabs, measurement and test
equipment ATE, satellite / audio / video tuners, wireless base stations and
antennas, power stages
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
75Ω version, monostable, 1 coil
Contact Data
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current, 23°C
Switching power
Max. Continuos RF-Power,
Breaking capacity max.
Contact material
Minimum switching voltage
Initial contact resistance
Operate time
Release time
Bounce time max.
Mechanical endurance
1) with appropriat cooling only
Coil Data
Coil voltage range
Coil versions, monostable
50Ω version, monostable, 1 coil
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil
code
51
52
53
56
57
01
02
03
05
06
Y-Design
Frequency range DC to 3GHz
Impedance 50Ω / 75Ω
Small dimensions (15x7.6x10.6mm)
1 form C contact (1 changeover contact)
Immersion cleanable
Low power consumption (≤140mW)
at 20°C., VSWR <1.2
without diode in parallel
with diode in parallel
voltage
Rated
VDC
4.5
4.5
12
24
12
3
5
3
5
9
Terminal assignment
Relay top view
Non-latching type,
not energized condition
140 mW
U
U
U
Coil Operating Range
nom
max.
op. min.
Operate
voltage
18.00
VDC
2.25
3.38
3.75
9.00
2.25
3.38
3.75
6.75
9.00
U
= Nominal coil voltage
= Upper limit of the operative range of
= Lower limit of the operative range of
nom.
the coil voltage (limiting voltage)
the coil voltage (reliable operate voltage)
nominal coil voltage
Limiting
voltage
10.90
26.10
52.30
10.90
19.60
26.10
VDC
6.50
9.80
6.50
9.80
Ambient Temperature [°C]
RF Signal Relays
HF3 S Relay
U
U
op. min.
rel. min.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
<100mΩ at 10mA/20mV
Release
typ. 3ms, max. 5ms
typ. 2ms, max. 5ms
typ. 4ms, max. 6ms
typ. 1ms, max. 3ms
voltage
220VDC, 250VAC
VDC
0.30
0.45
0.50
1.20
2.40
0.30
0.45
0.50
0.90
1.20
100W @ 3GHz
150W @ 2GHz
1 form C, 1 CO
Ag, Au covered
10
50W (2.5GHz)
60W, 62.5VA,
3 to 24VDC
7
Telecom-, Signal and RF Relays
HF3 S Relay
U
300W
100µV
operations
max.
2A
2A
resistance
at 0 A
Ω±10%
1028
4114
1028
1)
145
178
145
178
574
Coil
64
64
1)
1)
Latching type, 1 coil
rest condition
140 mW
Rated coil
power
mW
140
140
140
140
140
140
140
140
140
140
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Coil Data
Coil versions, bistable
50Ω version, bistable, 1 coil
50Ω version, bistable, 2 coils
75Ω version, bistable, 2 coils
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil
code
73S
91S
92S
93S
96S
41S
42S
43S
46S
70 mW
Relay top view
Non-latching type,
not energized condition
140 mW
U
U
U
U
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Coil Operating Range
nom
max.
op. min.
rel. min.
voltage
Rated
VDC
(continued)
4.5
4.5
12
12
5
3
5
3
5
3.5
2.5
1.5
0.5
3
2
1
0
U
U
= Nominal coil voltage
= Upper limit of the operative range of
= Lower limit of the operative range of
= Lower limit of the operative range of
-55 -45 -35 -25 -15 -5
nom.
nom.
the coil voltage (limiting voltage)
the coil voltage (reliable operate voltage)
For latching relays U
the coil voltage (reliable release voltage)
nominal coil voltage
nominal coil voltage
voltage
VDC
3.75
2.25
3.38
3.75
9.00
2.25
3.38
3.75
9.00
Set
Ambient Temperature [°C]
Latching type, 2 coils
reset condition
Ambient Temperature [°C]
U
U
op. min.
rel. min.
5
Limiting
voltage
15.30
10.90
26.10
10.90
26.10
15 25 35 45 55 65 75 85 95 105 115 125 135
VDC
6.50
9.80
6.50
9.80
U
op. min.
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
U
set min.
voltage
max.
-3.75
Reset
VDC
3.75
9.00
2.25
3.38
3.75
9.00
2.25
3.38
U
max.
at 0 A
at 0 A
resp
70 mW
Latching type, 1 coil
rest condition
resistance
140 mW
Ω±10%
.
1028
1028
U
357
145
178
145
178
Coil
64
64
reset
Axicom
min.
Sep. 07
Rated coil
power
mW
140
140
140
140
140
140
140
140
70
1
70 mW

Related parts for 2-1462051-2

2-1462051-2 Summary of contents

Page 1

... U nominal coil voltage nom. 1 0.5 U op. min. 0 -55 -45 -35 -25 - 105 115 125 135 Ambient Temperature [°C] Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. Axicom Latching type, 1 coil rest condition Sep 140 mW Coil ...

Page 2

... Category of environmental protection -0.03dB / -0.12dB / -0.30dB -0.03dB / -0.12dB / -0.30dB 50 50 1.05 / 1.10 / 1.25 1.05 / 1.10 / 1.25 Degree of protection, IEC 60529 -95dB / -80dB / -55dB -95dB / -80dB / -55dB Vibration resistance (functional) Shock resistance (functional), half sinus 11ms -0.03dB / -0.12dB / -0.30dB -0 ...

Page 3

... Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. (Continued) Bistable, 1 coil Contacts are shown in reset condition. Contact position might change during transportation and must be reset before use ...

Page 4

... Reel dimensions Time [s] Time [s] Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.tycoelectronics.com/definitions Axicom Tape and reel for SMT Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications ...

Page 5

... Axicom HF3 53 S Typical product code Coil type Part number Monostable 3-1462051-0 2-1462051-8 2-1462051-3 3-1462051-1 2-1462051-2 Bistable 1 coil 2-1462051-7 Bistable 2 coils 3-1462051-2 2-1462051-5 2-1462051-4 2-1462051-6 Monostable 3-1462050-0 3-1462050-1 3-1462050-2 3-1462050-3 3-1462050-7 Bistable 2 coils ...