DS1869-100 Maxim Integrated Products, DS1869-100 Datasheet
DS1869-100
Specifications of DS1869-100
Related parts for DS1869-100
DS1869-100 Summary of contents
Page 1
... SOIC and 8-pin DIP packages are available Standard resistance values for Dallastat - DS1869- DS1869- DS1869-100 ~ 100 k Operating temperature range: - Industrial differential supply operational range DESCRIPTION TM The DS1869 Dallastat is a digital rheostat or potentiometer. This device provides 64 possible uniform tap points over the entire resistive range. The standard resistive ranges are and 100 k . ...
Page 2
... Repetitive pulsed inputs can be used to step through each resistive position of the device in a relatively fast manner (see Figure 5b). The requirement for repetitive pulsed inputs is that pulses must be separated by a minimum time of 1 ms. If the input is not allowed to be inactive (high) for at least 1 ms, the DS1869 will interpret repetitive pulses as a single pulse. ...
Page 3
... All contact closure control inputs, UC, DC, and D, are internally pulled- 100 k =resistance. The UC and DC inputs are internally debounced and require no external components for input signal conditioning. DS1869 SINGLE PUSHBUTTON CONFIGURATION (TYPICAL EXAMPLE) Figure 1 DS1869 DUAL PUSHBUTTON CONFIGURATION (TYPICAL EXAMPLE) Figure 2A ...
Page 4
... DS1869 DUAL PORT CONFIGURATION (TYPICAL EXAMPLE) Figure 2B The DS1869 is provided with two supply inputs -V and +V. The maximum voltage difference between the two supply inputs is +8.0 volts. The minimum voltage difference is +2.7 volts. All input levels are referenced to the negative supply input, -V. The voltage applied to any Dallastat terminal must not exceed the negative supply voltage (- ...
Page 5
... FLOWCHART: ONE-BUTTON OPERATION AND ELECTRICAL CONTROL Figure 3 CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND 15 DS1869 ...
Page 6
... FLOWCHART: TWO-BUTTON OPERATION Figure 4 CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND 15 DS1869 ...
Page 7
... SYMBOL MIN TYP + 2.7V to 8.0V) SYMBOL MIN TYP - CC1 I CC2 R 400 W 750 (- + 2.7V to 8.0V) SYMBOL MIN TYP CPW HPW t 1 CCP DS1869 (- +85 C) MAX UNITS NOTES - MAX UNITS NOTES 1000 ppm/ C MAX UNITS NOTES ...
Page 8
... Pulses occurring faster than 1 ms apart may not be recognized as individual inputs but can be interpreted a constant input. Tolerance for pulse timing is 15% on minimum inputs. 9. Idle state supply current is measured with no pushbutton pressed and with the wiper R CMOS load. 10. For +V referenced 5V. 11. Valid only. t CPW DS1869 . IH tied ...