X9418WV24Z Intersil, X9418WV24Z Datasheet - Page 8

no-image

X9418WV24Z

Manufacturer Part Number
X9418WV24Z
Description
IC XDCP DUAL 64TAP 10K 24-TSSOP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9418WV24Z

Taps
64
Resistance (ohms)
10K
Number Of Circuits
2
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Resistance In Ohms
10K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9418WV24Z-2.7
Manufacturer:
Intersil
Quantity:
31
Figure 8. Detailed Potentiometer Block Diagram
DETAILED OPERATION
Both XDCP potentiometers share the serial interface
and share a common architecture. Each potentiometer
has a Wiper Counter Register and four Data
Registers. A detailed discussion of the register
organization and array operation follows.
Wiper Counter Register
The X9418 contains two wiper counter registers, one
for each XDCP potentiometer. The Wiper Counter
Register can be envisioned as a 6-bit parallel and
serial load counter with its outputs decoded to select
one of sixty-four switches along its resistor array. The
contents of the WCR can be altered in four ways: it
may be written directly by the host via the write Wiper
Counter Register instruction (serial load); it may be
written indirectly by transferring the contents of one of
four associated Data Registers via the XFR Data
Register instruction (parallel load); it can be modified
one step at a time by the Increment/Decrement
instruction. Finally, it is loaded with the contents of its
Data Register zero (DR0) upon power-up.
The WCR is a volatile register; that is, its contents are
lost when the X9418 is powered-down. Although the
register is automatically loaded with the value in DR0
upon power-up, it should be noted this may be
different from the value present at power-down.
If WCR = 00[H] then V
If WCR = 3F[H] then V
Serial Data Path
From Interface
Circuitry
W
W
/R
/R
W
W
= V
= V
8
Register 0
Register 2
L
H
/R
/R
L
H
8
Register 1
Register 3
Modified SCL
X9418
UP/DN
6
Data Registers
Each
Registers. These can be read or written directly by the
host and data can be transferred between any of the
four Data Registers and the Wiper Counter Register. It
should be noted all operations changing data in one of
these registers is a nonvolatile operation and will take
a maximum of 10ms.
If the application does not require storage of multiple
settings for the potentiometer, these registers can be
used as regular memory locations that could possibly
store system parameters or user preference data.
Register Descriptions
Data Registers, (6-Bit), Nonvolatile
Four 6-bit Data Registers for each XDCP. (eight 6-bit
registers in total).
– {D5~D0}: These bits are for general purpose not
(MSB)
volatile data storage or for storage of up to four
different wiper values. The contents of Data Register
0 are automatically moved to the Wiper Counter
Register on power-up.
NV
D5
Parallel
Bus
Input
UP/DN
CLK
Serial
Bus
Input
potentiometer
Register
Counter
INC/DEC
(WCR)
Wiper
Logic
NV
D4
C
D
o
u
n
e
e
o
d
e
t
r
c
D3
NV
has
four
NV
D2
nonvolatile
NV
D1
October 12, 2006
V
V
V
H
L
W
/R
/R
/R
(LSB)
H
L
FN8194.3
NV
D0
W
Data

Related parts for X9418WV24Z