MCP4021T-502E/SN Microchip Technology, MCP4021T-502E/SN Datasheet - Page 27

no-image

MCP4021T-502E/SN

Manufacturer Part Number
MCP4021T-502E/SN
Description
IC DGTL POT 5K 1CH 8SOIC
Manufacturer
Microchip Technology

Specifications of MCP4021T-502E/SN

Memory Type
Non-Volatile
Taps
64
Resistance (ohms)
5K
Number Of Circuits
1
Temperature Coefficient
150 ppm/°C Typical
Interface
Up/Down
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Resistance In Ohms
5K
End To End Resistance
5kohm
Resistance Tolerance
± 20%
No. Of Steps
64
Supply Voltage Range
2.7V To 5.5V
Control Interface
2 Wire, Serial
No. Of Pots
Single
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP4XXXDM-DB - BOARD DAUGHTER DIGIPOT MCP4XXXMCP402XEV - BOARD EVAL FOR MCP402X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
5.0
5.1
The MCP4021/2/3/4 utilizes a simple 2-wire interface to
increment or decrement the digital potentiometer’s
wiper terminal (W), store the wiper setting in non-vola-
tile memory and turn the WiperLock technology feature
on or off. This interface uses the Chip Select (CS) pin,
while the U/D pin is the Up/Down input.
The Increment/Decrement protocol enables the device
to move one step at a time through the range of
possible resistance values. The wiper value is initial-
ized with the value stored in the internal EEPROM
upon power-up. A wiper value of 00h connects the
wiper to terminal B. A wiper value of 3Fh connects the
wiper to terminal A. Increment commands move the
wiper toward terminal A, but will not increment to a
value greater than 3Fh. Decrement commands move
the wiper toward terminal B, but will not decrement
below 00h.
Refer to
AC/DC Electrical Characteristics table for detailed input
threshold and timing specifications.
Communication is unidirectional. Therefore, the value
of the current wiper setting cannot be read out of the
MCP402X device.
TABLE 5-1:
© 2005 Microchip Technology Inc.
Increment without Writing Wiper Setting to EEPROM
Increment with Writing Wiper Setting to EEPROM
Decrement without Writing Wiper Setting to EEPROM
Decrement with Writing Wiper Setting to EEPROM
Write Wiper Setting to EEPROM
High-Voltage Increment and Disable WiperLock Technology
High-Voltage Increment and Enable WiperLock Technology
High-Voltage Decrement and Disable WiperLock Technology
High-Voltage Decrement and Enable WiperLock Technology
Write Wiper Setting to EEPROM and Disable WiperLock
Technology
Write Wiper Setting to EEPROM and Enable WiperLock
Technology
Note 1: This command will only complete if wiper is “unlocked” (WiperLock Technology is Disabled).
SERIAL INTERFACE
Overview
Section 1.0 “Electrical
COMMANDS
Command Name
Characteristics”,
5.2
The MCP402X devices support 10 serial commands.
The commands can be grouped into the following
types:
• Serial Commands
• High-voltage Serial Commands
All the commands are shown in Table 5-1.
The command type is determined by the voltage level
on the CS pin. The initial state that the CS pin must be
driven is V
can be driven are:
• V
• V
If the CS pin is driven from V
mand is selected. If the CS pin is driven from V
V
High-voltage serial commands control the state of the
WiperLock technology. This is a unique feature, where
the user can determine whether or not to “lock” or
“unlock” the wiper state.
High-voltage serial commands increment/decrement
the wiper regardless of the status of the WiperLock
technology.
IHH
IL
IHH
EEPROM
, a high-voltage serial command is selected.
Value in
Saves
Wiper
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Serial Commands
IH
. From V
MCP4021/2/3/4
Voltage
on CS
High
pin?
Yes
Yes
Yes
Yes
Yes
Yes
IH
, the two levels that the CS pin
”unlocked”
Command
“locked”/
unlocked
unlocked
unlocked
unlocked
unlocked
unlocked
unlocked
unlocked
Wiper is
locked
locked
locked
IH
After
to V
DS21945C-page 27
IL
, a serial com-
“locked”?
Wiper is
Works
Note 1
Note 1
Note 1
Note 1
Note 1
when
Yes
Yes
Yes
Yes
Yes
Yes
IH
to

Related parts for MCP4021T-502E/SN