MCP4651-503E/ST Microchip Technology, MCP4651-503E/ST Datasheet - Page 15

no-image

MCP4651-503E/ST

Manufacturer Part Number
MCP4651-503E/ST
Description
IC DGTL POT 50K 256TAPS 14-TSSOP
Manufacturer
Microchip Technology
Datasheet

Specifications of MCP4651-503E/ST

Package / Case
14-TSSOP
Taps
257
Resistance (ohms)
50K
Number Of Circuits
2
Temperature Coefficient
150 ppm/°C Typical
Memory Type
Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Resistance In Ohms
50K
Number Of Pots
Dual
Taps Per Pot
256
Resistance
50 KOhms
Wiper Memory
Volatile
Digital Interface
Serial (2-Wire, I2C)
Operating Supply Voltage
2.5 V or 3.3 V or 5 V
Supply Current
0.0025 mA (Typ)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
TABLE 1-2:
© 2008 Microchip Technology Inc.
I
Note 1:
2
102A
102B
103A
103B
Param.
C AC Characteristics
No.
106
2:
3:
4:
5:
6:
7:
(5)
(5)
(5)
(5)
As a transmitter, the device must provide this internal minimum delay time to bridge the undefined region
(minimum 300 ns) of the falling edge of SCL to avoid unintended generation of START or STOP conditions.
A fast-mode (400 kHz) I
requirement t
stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal,
it must output the next data bit to the SDA line
T
the SCL line is released.
The MCP46X1/MCP46X2 device must provide a data hold time to bridge the undefined part between V
and V
must be tested in order to ensure that the output data will meet the setup and hold specifications for the
receiving device.
Use Cb in pF for the calculations.
Not Tested
A Master Transmitter must provide a delay to ensure that difference between SDA and SCL fall times do
not unintentionally create a Start or Stop condition.
Ensured by the T
T
R
T
T
T
T
HD:DAT
Sym
max.+t
RSDA
RSCL
FSDA
FSCL
IL
I
2
of the falling edge of the SCL signal. This specification is not a part of the I
C BUS DATA REQUIREMENTS (SLAVE MODE) (CONTINUED)
SU;DAT
Characteristic
Data input hold
SDA rise time
SCL rise time
SCL fall time
SDA fall time
SU;DAT
AA
= 1000 + 250 = 1250 ns (according to the standard-mode I
time
3.4 MHz specification test.
≥ 250 ns must then be met. This will automatically be the case if the device does not
2
C-bus device can be used in a standard-mode (100 kHz) I
Standard Operating Conditions (unless otherwise specified)
Operating Temperature
Operating Voltage V
1.7 MHz mode
1.7 MHz mode
3.4 MHz mode
3.4 MHz mode
1.7 MHz mode
3.4 MHz mode
1.7 MHz mode
3.4 MHz mode
1.7 MHz mode
3.4 MHz mode
1.7 MHz mode
3.4 MHz mode
100 kHz mode
400 kHz mode
100 kHz mode
400 kHz mode
100 kHz mode
400 kHz mode
100 kHz mode
400 kHz mode
100 kHz mode
400 kHz mode
MCP453X/455X/463X/465X
20 + 0.1Cb
20 + 0.1Cb
20 + 0.1Cb
20 + 0.1Cb
DD
range is described in
Min
20
20
10
10
20
10
20
10
20
10
0
0
0
0
–40°C ≤ T
(4)
1000
1000
Max
300
160
300
160
300
300
300
300
160
80
40
80
80
80
40
80
A
≤ +125°C (Extended)
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
AC/DC characteristics
2
C bus specification) before
Cb is specified to be from
10 to 400 pF (100 pF maxi-
mum for 3.4 MHz mode)
After a Repeated Start con-
dition or an Acknowledge
bit
After a Repeated Start
condition or an Acknowl-
edge bit
Cb is specified to be from
10 to 400 pF (100 pF max
for 3.4 MHz mode)
Cb is specified to be from
10 to 400 pF (100 pF max
for 3.4 MHz mode)
Cb is specified to be from
10 to 400 pF (100 pF max
for 3.4 MHz mode)
1.8V-5.5V, Note 6
2.7V-5.5V, Note 6
4.5V-5.5V, Note 6
4.5V-5.5V, Note 6
2
2
C specification, but
C-bus system, but the
Conditions
DS22096A-page 15
IH