AR1010-I/ML Microchip Technology, AR1010-I/ML Datasheet - Page 17

IC TOUCH SCREEN CTRLR 20-QFN

AR1010-I/ML

Manufacturer Part Number
AR1010-I/ML
Description
IC TOUCH SCREEN CTRLR 20-QFN
Manufacturer
Microchip Technology
Type
Resistiver
Datasheets

Specifications of AR1010-I/ML

Resolution (bits)
10 b
Touch Panel Interface
4-Wire, 5-Wire, 8-Wire
Number Of Inputs/keys
3 Key
Data Interface
UART
Data Rate/sampling Rate (sps, Bps)
9.6k
Voltage - Supply
3.3 V ~ 5 V
Current - Supply
17mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-VQFN Exposed Pad, 20-HVQFN, 20-SQFN, 20-DHVQFN
Voltage Supply Source
Single Supply
Controller Type
Touch Screen
Supply Voltage Range
3.3V To 5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
QFN
No. Of Pins
20
Interface
UART
Filter Terminals
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AR1010-I/ML
Manufacturer:
Microchip
Quantity:
1 206
Part Number:
AR1010-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Changing the Number of Calibration Points
Method 1:
Method 2:
Calibrating the Controller
The points used for the calibration is determined by the “CalType” registry entry described in
section “Changing the Calibration Type” below.
found in under the “Windows” directory on the CE Device.
Windows CE Calibration Registry Entries
Calibration parameters are created by Hcecal after calibration and are stored in the registry under
the following key:
Upon boot, if the registry entries are not located, the driver defaults to a default un-calibrated
state.
If no shortcut is present under “Programs” group, a shortcut to the calibration application may be
6. Configuring TSHARC Controller
In "Platform Builder 4.2", click on the FileView tab
Double click on the appropriate registry file <WINCEROOT>\PUBLIC\COMMON\OAK
Change the value of "CalType" appropriately
Rebuild and recreate run-time image.
Using a registry editor for the target device, change the “CalType” registry item located
within the “HKEY_LOCAL_MACHINE\SOFTWARE\Hampshire\CurrentVersion\CalType”
branch according to the following:
Browse to the “Windows” directory using Windows Explorer and double-click the shortcut
“TouchIOCTL”. This will cause current TSHARC driver to re-read and apply the new
registry settings.
Select the Start menu
Under the “Programs” group select “TSHARC Calibration”
Touch all targets with activator tip for at least a couple seconds each.
[HKEY_LOCAL_MACHINE\SOFTWARE\Hampshire\CurrentVersion\Global]
o
o
o
o
o
o
o
o
o
o
o
If Serial
If PS/2
If USB
For 3-point calibration, set value to "dword:3"
For 4-point calibration, set value to "dword:4"
For 7-point calibration, set value to "dword:7"
For 20-point calibration, set value to "dword:14"
For 3-point calibration, set value to "dword:3"
For 4-point calibration, set value to "dword:4"
For 7-point calibration, set value to "dword:7"
For 20-point calibration, set value to "dword:14"
\DRIVERS\TSHARC\TSHARCS\TSHARCS.reg
\DRIVERS\TSHARC\TSHARCP\TSHARCP.reg
\DRIVERS\TSHARC\TSHARCU\TSHARCU.reg
17