788395-1 TE Connectivity, 788395-1 Datasheet - Page 5

WIRE-BOARD CONNECTOR, RCPT 80POS 1.27MM

788395-1

Manufacturer Part Number
788395-1
Description
WIRE-BOARD CONNECTOR, RCPT 80POS 1.27MM
Manufacturer
TE Connectivity
Datasheets

Specifications of 788395-1

Peak Reflow Compatible (260 C)
No
Pitch Spacing
0.05"
Current Rating
1A
Body Material
Liquid Crystal Polymer
No. Of Rows
4
Leaded Process Compatible
No
Mounting Type
PCB
Rohs Compliant
Yes
Product Type
Connector
Profile
High
Pcb Mount Style
Through Hole Press Fit
Pcb Mount Retention
With
Pcb Mounting Orientation
Vertical
Type Of Connector
Blindmate
Pcb Mount Alignment
With
Pcb Mount Alignment Type
Post Polarization
Retention Leg Material
Brass
Color
Black
Sealed Bottom
Without
Product Series
Series I
Termination Post Length (mm [in])
3.43 [0.135]
Solder Tail Contact Plating
Tin-Lead over Nickel
Number Of Positions
80
Centerline (mm [in])
1.27 [0.050]
Pcb Mount Retention Type
Boardlock(s)
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Phosphor Bronze
Connector Style
Receptacle
Housing Temperature Rating
Standard
Housing Material
Liquid Crystal Polymer (LCP)
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Printed Circuit Board
Application
SCA2 (Single Connector Attachment), SCSI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
788395-1
Manufacturer:
AMP
Quantity:
38 111
4.
4.1.
4.2.
4.3.
4.4.
Rev A
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that product meets requirements of Figure 2. Failures attributed to
equipment, test setup or operator deficiencies shall not disqualify product. When product failure occurs,
corrective action shall be taken and samples resubmitted for qualification. Testing to confirm corrective
action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with applicable product drawing and
this specification.
Sample Selection
Samples shall be prepared in accordance with applicable Instruction Sheets and shall be selected
at random from current production. All test groups shall each consist of a minimum of 5 samples.
Test Sequence
Qualification inspection shall be verified by testing samples as specified in Figure 3.
Termination Resistance Measurement Points
Figure 4
108-1548
5 of 7

Related parts for 788395-1