5-747916-5 TE Connectivity, 5-747916-5 Datasheet
5-747916-5
Specifications of 5-747916-5
Available stocks
Related parts for 5-747916-5
5-747916-5 Summary of contents
Page 1
... Qualification Test Results Successful qualification testing on the subject product line was originally completed on 23Oct89. Additional qualification testing was successfully completed on 06Aug03. The Qualification Test Report number for this testing is 501-102. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. ...
Page 2
... Visual inspection. EIA-364-23. Subject specimens to 100 milliamperes maximum and 20 millivolts maximum open circuit voltage. See Figure 3. EIA-364-21. 500 volts DC, 2 minute hold. Test between adjacent contacts of unmated specimens. EIA-364-20, Condition I. 1000 volts AC at sea level. Test between adjacent contacts of unmated specimens. ...
Page 3
... Measure force necessary to mate specimens at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-13. Measure force necessary to unmate specimens at a maximum rate of 12.7 mm [.5 in] per minute. EIA-364-32, Test Condition VII. Subject mated specimens to 5 cycles between -55 and 105°C. EIA-364-31, Method IV. ...
Page 4
... Numbers indicate sequence in which tests are performed. (c) Precondition specimens with 10 durability cycles. Rev B Requirement See Note. Figure 1 (end) Test Group ( Test Sequence ( 3,7 2,4 2 3(c) 3( Figure 2 108-40031 Procedure EIA-364-65, Class IIIA (4 gas). Subject mated specimens to environmental Class IIIA for 20 days 2,4 2,6 3 ...
Page 5
... AWG wire. Test groups 2 and 4 shall each consist position specimens with gold flash, all terminated to 20 AWG wire. Test group 3 shall consist position specimens with both gold flash and 30 µin gold plating, all terminated to 20 AWG wire ...
Page 6
Low Level Contact Resistance Measurement Points Rev B Figure 3 108-40031 ...