Datasheets

Specifications of 4-644807-5

Connector Type
Connector Assembly
Connector Design
Closed End
Product Line
MTA-156 Posted
Termination Method To Wire/cable
IDC Standard
Wire Size (mm² [awg])
0.8-0.9² [18]
Mating Connector Lock
With
Four Points Of Contact
Without
Shrouded
Yes
Mounting Ears
Without
Panel Mount Retention
Without
Solder Tail Contact Plating
Bright Tin
Number Of Positions
15
Centerline (mm [in])
3.96 [0.156]
Cable Exit Angle
90°
Contact Type
Pin
Contact Shape
Square
Contact Plating, Mating Area, Material
Gold (30) or (30) Total Gold Flash over Palladium Nickel
Contact Base Material
Copper Alloy
Connector Style
Plug
Housing Color
Orange
Mating Alignment
Without
Ul Flammability Rating
UL 94V-2
Housing Material
Nylon
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Wire/Cable
Application Use
Wire-to-Wire
1.
1.1.
1.2.
2.
3.
3.1.
3.2.
3.3.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers the performance requirements for the TE Connectivity (TE) MTA 156
connector wire-to-wire system. This system provides a reliable interconnection between wires in
appliances, vending machines, computers and other sophisticated commercial equipment.
Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
APPLICABLE DOCUMENTS
The following TE documents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the document applies. In the event of conflict between the
requirements of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirements of this specification and the referenced documents,
this specification shall take precedence.
!
!
!
REQUIREMENTS
Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.
Materials
!
!
Ratings
!
!
109-1: General Requirements for Test Specifications
109 Series: Test Specifications as indicated in Figure 1
114-1020: Connector MTA 156, Application of
Contact:
Housing:
Current/Voltage: 600 volts AC at 7 amperes maximum
Operating Temperature: -55 to 105° C
NOTE
Post: Brass, post tin plated
Receptacle: Phosphor bronze, post tin plated
2 through 10 position: Nylon 6/6, UL94V-2
11 through 24 position: Nylon 6/12, UL94V-2
The maximum rated current that can be carried by this product is limited by the
maximum operating temperature of the housings (105°C) and the temperature rise of the
contacts (30° C). Variables which shall be considere d for each application are: wire size,
connector size, contact material, and ambient temperature.
| Indicates change
*Trademark
Product
Specification
Connector, MTA 156, Wire-To-Wire System
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1065
11Mar11 Rev F
1 of 7
LOC B

Related parts for 4-644807-5

4-644807-5 Summary of contents

Page 1

... Receptacle: Phosphor bronze, post tin plated ! Housing: • 2 through 10 position: Nylon 6/6, UL94V-2 • 11 through 24 position: Nylon 6/12, UL94V-2 3.3. Ratings ! Current/Voltage: 600 volts amperes maximum The maximum rated current that can be carried by this product is limited by the NOTE maximum operating temperature of the housings (105°C) and the temperature rise of the contacts (30° ...

Page 2

... See Figure 4. See Note. MECHANICAL Wire Size Slot Tensile (AWG) (Lb minimum) 26 5.0 24 8.0 22 12.0 20 17.0 18 30.0 Figure 1 (continued) ...

Page 3

... Mount connector in fixture. TE Spec 109-30. Pull on contact using special cut- away housing. TE Spec 109-42. Measure force necessary to mate connector assembly with locking latches intact, a distance of .150 inch from point of initial contact using free floating fixtures at a rate of 0 ...

Page 4

... Durability Contact retention Mating force Unmating force Thermal shock Humidity-temperature cycling (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) One half of the samples shall be subjected to the straight tensile test and the remaining half to the perpendicular tensile test. Rev F ...

Page 5

... Test groups 2 through 6 shall consist of 2 connector assemblies per group per wire size. Test group 7 shall consist of 15 contacts chosen randomly from 5 connector assemblies. Test group 8 shall consist of 4 connector assemblies per wire size. Each wire size shall consist of solid, stranded and prefused or overcoated wire ...

Page 6

A 1 foot minimum length of continuous lead for heat dissipation. NOTE 2. Termination resistance equals millivolts divided by test current less resistance of 6 inches of wire. Temperature and Resistance Measurement Points Rev F Figure 3 108-1065 6 ...

Page 7

... Rev F Figure 4 Terminal Temperature vs Current/Circuit 24 Circuit Assembly 108-1065 ...

Related keywords