AD7785BRUZ Analog Devices Inc, AD7785BRUZ Datasheet - Page 6

no-image

AD7785BRUZ

Manufacturer Part Number
AD7785BRUZ
Description
IC ADC 20BIT SIGMA-DELTA 16TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7785BRUZ

Data Interface
MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
20
Sampling Rate (per Second)
470
Number Of Converters
1
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
20bit
Input Channel Type
Differential
Supply Voltage Range - Analogue
2.7V To 5.25V
Supply Voltage Range - Digital
2.7V To 5.25V
Supply
RoHS Compliant
Sampling Rate
470Hz
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7785EBZ - BOARD EVALUATION FOR AD7785
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7785BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7785BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7785BRUZ-REEL
Manufacturer:
ADI
Quantity:
1 000
AD7785
TIMING CHARACTERISTICS
AV
Table 2.
Parameter
t
t
Read Operation
Write Operation
1
2
3
4
5
6
3
4
Sample tested during initial release to ensure compliance. All input signals are specified with t
See Figure 3 and Figure 4.
These numbers are measured with the load circuit shown in Figure 2 and defined as the time required for the output to cross the V
SCLK active edge is the falling edge of SCLK.
These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit shown in Figure 2. The measured number
is then extrapolated back to remove the effects of charging or discharging the 50 pF capacitor. This means that the times quoted in the timing characteristics are the
true bus relinquish times of the part and, as such, are independent of external bus loading capacitances.
RDY returns high after a read of the ADC. In single conversion mode and continuous conversion mode, the same data can be read again, if required, while RDY is high,
although care should be taken to ensure that subsequent reads do not occur close to the next output update. In continuous read mode, the digital word can be read
only once.
t
t
t
t
t
t
t
t
t
1
2
5
6
7
8
9
10
11
DD
3
5, 6
= 2.7 V to 5.25 V, DV
1, 2
Limit at T
100
100
0
60
80
0
60
80
10
80
0
10
0
30
25
0
DD
= 2.7 V to 5.25 V, GND = 0 V, Input Logic 0 = 0 V, Input Logic 1 = DV
MIN
, T
MAX
(B Version)
OUTPUT
Figure 2. Load Circuit for Timing Characterization
PIN
TO
50pF
Rev. 0 | Page 6 of 32
Unit
ns min
ns min
ns min
ns max
ns max
ns min
ns max
ns max
ns min
ns max
ns min
ns min
ns min
ns min
ns min
ns min
I
100µA WITH DV
I
100µA WITH DV
SINK
SOURCE
(1.6mA WITH DV
(200µA WITH DV
1.6V
Conditions/Comments
DD
DD
SCLK high pulse width
SCLK low pulse width
CS falling edge to DOUT/RDY active time
DV
DV
SCLK active edge to data valid delay
DV
DV
Bus relinquish time after CS inactive edge
SCLK inactive edge to CS inactive edge
SCLK inactive edge to DOUT/RDY high
CS falling edge to SCLK active edge setup time
Data valid to SCLK edge setup time
Data valid to SCLK edge hold time
CS rising edge to SCLK edge hold time
R
= t
= 3V)
= 3V)
DD
DD
DD
DD
F
DD
= 5 ns (10% to 90% of DV
= 4.75 V to 5.25 V
= 2.7 V to 3.6 V
= 4.75 V to 5.25 V
= 2.7 V to 3.6 V
= 5V,
DD
= 5V,
DD
, unless otherwise noted.
DD
) and timed from a voltage level of 1.6 V.
OL
or V
OH
4
limits.
4

Related parts for AD7785BRUZ