DS12885S+T&R Maxim Integrated Products, DS12885S+T&R Datasheet
DS12885S+T&R
Specifications of DS12885S+T&R
Related parts for DS12885S+T&R
DS12885S+T&R Summary of contents
Page 1
... Optional 28-Pin PLCC Surface Mount Package 32-Pin TQFP (DS12885) RESET ♦ Optional Encapsulated DIP (EDIP) Package with RCLR Integrated Crystal and Battery (DS12887, DS12887A, DS12C887, DS12C887A) ♦ Optional Industrial Temperature Range Available SQW ♦ Underwriters Laboratory (UL) Recognized V BAT ______________________________________________ Maxim Integrated Products Real-Time Clocks Features 1 ...
Page 2
Real-Time Clocks ABSOLUTE MAXIMUM RATINGS Voltage Range on V Pin Relative to Ground .....-0.3V to +6.0V CC Operating Temperature Range ................................................... Commercial (noncondensing) .............................0°C to +70°C Operating Temperature Range ................................................... Industrial (noncondensing)...............................-40°C to +85°C Storage Temperature Range EDIP ..................................................................-40°C to ...
Page 3
DC ELECTRICAL CHARACTERISTICS ( 3.0V over the operating range, unless otherwise noted.) (Note 2) CC BAT A PARAMETER SYMBOL V Current (OSC On); BAT T = +25° 3.0V A BACKUP V Current ...
Page 4
Real-Time Clocks AS t ASD AD0–AD7 WRITE AD0–AD7 READ AS t ASD DS t ASD R ASL AD0–AD7 WRITE 4 _____________________________________________________________________ Motorola Bus Read/Write Timing PW ASH t ASED t CYC ...
Page 5
AS t ASD DS t ASD R/W CS AD0–AD7 IRQ Release Delay Timing DS RESET IRQ t IRDS PF(MAX) V PF(MIN) RECOGNIZED INPUTS VALID OUTPUTS t CYC PW ASH t ASED ...
Page 6
Real-Time Clocks POWER-UP/POWER-DOWN CHARACTERISTICS (T = -40°C to +85°C) (Note 2) A PARAMETER SYMBOL Recovery at Power-Up V Fall Time PF(MAX) V PF(MIN) V Rise Time PF(MIN) V PF(MAX) DATA RETENTION (T = +25°C) ...
Page 7
T = +25°C, unless otherwise noted vs. V BAT1 BAT vs. TEMPERATURE +85°C CC 300 250 0°C +70°C +40°C 200 -40°C 150 2.5 2.8 3.0 3.5 3.3 V (V) BAT X1 ...
Page 8
Real-Time Clocks PIN SO, EDIP PLCC TQFP PDIP — — 5–10, 4–11 4– 15, 20 12, 17 ...
Page 9
PIN SO, NAME EDIP PLCC TQFP PDIP 11, 15, 20, 22 16, 20, 13, 18, 23, 25 RESET Connection. This ...
Page 10
Real-Time Clocks PIN SO, EDIP PLCC TQFP PDIP — (DS12887A DS12C887A ____________________________________________________________________ Pin Description (continued) NAME Active-Low Interrupt Request Output. ...
Page 11
Detailed Description The DS12885 family of RTCs provide 14 bytes of real- time clock/calendar, alarm, and control/status registers and 114 bytes (113 bytes for DS12C887 and DS12C887A) of nonvolatile, battery-backed static RAM. A time-of-day alarm, three maskable interrupts with a ...
Page 12
Real-Time Clocks Clock Accuracy The accuracy of the clock is dependent upon the accu- racy of the crystal and the accuracy of the match between the capacitive load of the oscillator circuit and the capacitive load for which the crystal ...
Page 13
The three alarm bytes can be used in two ways. First, when the alarm time is written in the appropriate hours, minutes, and seconds alarm locations, the alarm inter- rupt is initiated at the specified time each day, if the ...
Page 14
Real-Time Clocks Table 2B. Time, Calendar, and Alarm Data Modes—Binary Mode ( ADDRESS BIT 7 BIT 6 BIT 5 00H 0 0 01H 0 0 02H 0 0 03H 0 0 AM/PM 04H AM/PM 0 ...
Page 15
Control Registers The real-time clocks have four control registers that are accessible at all times, even during the update cycle. MSB BIT 7 BIT 6 BIT 5 UIP DV2 Bit 7: Update-In-Progress (UIP). This bit is a status flag that ...
Page 16
Real-Time Clocks MSB BIT 7 BIT 6 BIT 5 SET PIE Bit 7: SET. When the SET bit is 0, the update transfer functions normally by advancing the counts once per second. When the SET bit is written to 1, ...
Page 17
MSB BIT 7 BIT 6 BIT 5 IRQF PF Bit 7: Interrupt Request Flag (IRQF). This bit is set to 1 when any of the following are true PIE = AIE = ...
Page 18
Real-Time Clocks Century Register (DS12C887/DS12C887A Only) The century register at location 32h is a BCD register designed to automatically load the BCD value 20 as the year register changes from 99 to 00. The MSB of this register is not ...
Page 19
Table 3. Periodic Interrupt Rate and Square-Wave Output Frequency SELECT BITS t PERIODIC PI REGISTER A INTERRUPT RATE RS3 RS2 RS1 RS0 None 3.90625ms 7.8125ms ...
Page 20
Real-Time Clocks TOP VIEW MOT AD0 4 AD1 5 DS12885 AD2 6 DS12885S AD3 7 AD4 8 AD5 9 AD6 10 AD7 11 GND 12 SO, PDIP NOTE: THE DS12887A AND DS12C887A CANNOT BE STORED ...
Page 21
PART TEMP RANGE DS12885+ 0°C to +70°C DS12885N+ -40°C to +85°C DS12885Q+ 0°C to +70°C DS12885QN+ -40°C to +85°C DS12885Q+T&R 0°C to +70°C DS12885QN+T&R -40°C to +85°C DS12885S+ 0°C to +70°C DS12885SN+ -40°C to +85°C DS12885S+T&R 0°C to +70°C DS12885T+ ...
Page 22
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 22 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2010 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc ...