ISL12025IBZ-T Intersil, ISL12025IBZ-T Datasheet - Page 14

no-image

ISL12025IBZ-T

Manufacturer Part Number
ISL12025IBZ-T
Description
IC RTC/CALENDAR EEPROM 8-SOIC
Manufacturer
Intersil
Type
Clock/Calendar/Supervisor/EEPROMr
Datasheet

Specifications of ISL12025IBZ-T

Memory Size
4K (512 x 8)
Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Alarm 1 and AL0 for Alarm 0), indicate if an alarm has
happened. The AL1 and AL0 bits in the status register are
reset by the falling edge of the eighth clock of status register
read.
There are two alarm operation modes: Single Event and
periodic Interrupt Mode:
Writing to the Alarm Registers
The Alarm Registers are non-volatile but require special
attention to insure a proper non-volatile write takes place.
Specifically, byte writes to individual registers are good for all
but registers 0006h and 0000Eh, which are the DWA0 and
DWA1 registers, respectively. Those registers will require a
special page write for nonvolatile storage. The
recommended page write sequences are as follows:
1. Single Event Mode is enabled by setting the AL0E or
2. Interrupt Mode (or “Pulsed Interrupt Mode” or PIM) is
1. 16-byte page writes: The best way to write or update the
AL1E bit to “1”, the IM bit to “0”, and disabling the
frequency output. This mode permits a one-time match
between the alarm registers and the RTC registers. Once
this match occurs, the AL0 or AL1 bit is set to “1”. Once
the AL0 or AL1 bit is read, this will automatically resets it.
Both Alarm registers can be set at the same time to
trigger alarms. Polling the SR will reveal which alarm has
been set.
enabled by setting the AL0E or AL1E bit to “1” the IM bit
to “1”, and disabling the frequency output. If both AL0E
and AL1E bits are set to 1, then only the AL0E PIM alarm
will function (AL0E overrides AL1E). This means that
once the Interrupt Mode alarm is set, it will continue to
alarm for each occurring match of the alarm and present
time. This mode is convenient for hourly or daily
hardware interrupts in microcontroller applications such
as security cameras or utility meter reading. Interrupt
Mode CANNOT be used for general periodic alarms,
however, since a specific time period cannot be
programmed for interrupt, only matches to a specific time
of day. The Interrupt Mode is only stopped by disabling
the IM bit or the Alarm Enable bits.
Alarm Registers is to perform a 16-byte write beginning at
address 0001h (MNA0) and wrapping around and ending
at address 0000h (SCA0). This will insure that
non-volatile storage takes place. This means that the
code must be designed so that the Alarm0 data is written
starting with Minutes register, and then all the Alarm1
data, with the last byte being the Alarm0 Seconds (the
page ends at the Alarm1 Y2k register and then wraps
around to address 0000h).
Alternatively, the 16-byte page write could start with
address 0009h, wrap around and finish with address
0008h. Note that any page write ending at address
0007h or 000Fh (the highest byte in each Alarm) will not
trigger a nonvolatile write, so wrapping around or
overlapping to the following Alarm's Seconds register is
advised.
14
ISL12025
If the Alarm1 is used, SCA1 would need to have the correct
data written.
Power Control Operation
The power control circuit accepts a V
Many types of batteries can be used with Intersil RTC
products. For example, 3.0V or 3.6V Lithium batteries are
appropriate, and battery sizes are available that can power
an Intersil RTC device for up to 10 years. Another option is
to use a Super Cap for applications where V
for up to a month. See the “Application Section” on page 21
for more information.
There are two options for setting the change-over conditions
from V
register controls this operation.
Note that the I
battery backup, which is controlled by the SBIB bit. See
“Backup Battery Operation” on page 23 for information.
The V
circuit to protect from incorrect serial bus writes after a
brownout situation. This circuit disables the serial bus for
about 90ms following the power-up. To trigger the delay, the
VDD must drop below the battery trip point yet stay above
approximately 1.0V (limit of active circuit operation). After
that, the power-up ramp must be slower than 0.25V/ms to
trigger the delay. To be safe, serial interface software may
need to consider the 90ms delay in all power-up routines.
OPTION 1 - STANDARD (POWER CONTROL) MODE
In the Standard Mode, the supply will switch over to the
battery when V
lower. In this mode, accidental operation from the battery is
prevented since the battery backup input will only be used
when the V
To select Option 1, BSW bit in the Power Register must be
set to “BSW = 0”. A description of power switchover follows.
2. Other non-volatile writes: It is possible to do writes of
- Option 1 - Standard Mode
- Option 2 - Legacy Mode (Default)
less than an entire page, but the final byte must always
be addresses 0000h through 0004h or 0008h though
000Ch to trigger a non-volatile write. Writing to those
blocks of 5 bytes sequentially, or individually, will trigger a
non-volatile write. If the DWA0 or DWA1 registers need to
be set, then enough bytes will need to be written to
overlap with the other Alarm register and trigger the
non-volatile write. For Example, if the DWA0 register is
being set, then the code can start with a multiple byte
write beginning at address 0006h, and then write 3 bytes
ending with the SCA1 register as follows:
Addr
0006h DWA0
0007h Y2K0
0008h SCA1
DD
DD
/V
to Battery Backup Mode. The BSW bit in the PWR
Name
BAT
DD
2
supply is shut off.
DD
C bus may or may not be operational during
power circuit also contains a glitch detection
drops below V
TRIP
DD
or V
and a V
BAT
DD
, whichever is
is interrupted
BAT
August 13, 2008
input.
FN6371.3