179610-1 TE Connectivity, 179610-1 Datasheet - Page 6

AMP CT CRIMP-2 REC CONT. L/P

179610-1

Manufacturer Part Number
179610-1
Description
AMP CT CRIMP-2 REC CONT. L/P
Manufacturer
TE Connectivity
Datasheets

Specifications of 179610-1

Product Type
Contact
Termination Method To Wire/cable
Crimp
Contact - Rated Current (a)
2
Operating Voltage Reference
AC/DC, AC, DC
Operating Voltage (vac)
125
Operating Voltage (vdc)
125
Wire/cable Size (awg)
26 – 30
Mating Retention
Without
Contact Type
Socket
Contact Plating, Mating Area, Material
Pre-Tin
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Operating Temperature (°c [°f])
-30 – +105 [-22 – +221]
Applies To
Wire/Cable
Accepts Wire Insulation Diameter, Range (mm [in])
0.65 – 1.35 [0.0255 – 0.053]
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Packaging Method
Loose Piece
ASHL-0005- ES REV B
3.8.3 (1)
3.8.3 (2)
3.8.3 (3)
3.8.3 (4)
3.8.3 (5)
3.8.3 (6)
3.8.3 (7)
Para.
Vibration
Sinusoidal
Low Frequency
Physical Shock
Temperature
Life
Resistance to
Cold
Humidity,
Steady State
Thermal Shock
Salt Spray
Test Items
AMP Shanghai Ltd.
Tyco Electronics
No electrical discontinuity greater than 1
microsecond shall occur.
Termination resistance (low level) shall be
met.
No electrical discontinuity greater than 1
microsecond shall occur.
Termination resistance (low level) shall be
met.
Termination resistance (low level) shall be
met.
Termination resistance (low level) shall be
met.
Insulation resistance (Final) 500 MΩ Min.
Termination resistance (low level) shall be
met.
Termination resistance (low level) shall be
met.
Resistance (low level) (Final) must meet
visual & electrical requirements, which
applicable.
Environmental Performance Requirements
Fig. 2 (To be continued)
Requirements
6 of 11
PAGE
Document No.
108-5408
Subject mated connectors to 10-
55-10 Hz traversed in 1 minute
at 1.52 mm amplitude 2 hours
each of 3 mutually
perpendicular planes.
MIL-STD-202, Method 201,
Condition A.
Subject mated connectors to
490.3 m/s
pulses of 11milisecond
duration; 3 shocks in each
direction applied along the 3
mutually perpendicular planes
total 18 shocks.
MIL-STD-202, Method 213,
Condition A.
Subject mated connectors to
temperature life; testing
atmosphere at 85±2
hours.
Subject mated connectors to
cold testing atmosphere at -25
±3
Subsequent measurement shall
be done after reconditioning in
the room temperature for 1
hour.
Subject mated connectors to
steady state humidity at 40
and 90~95 % R.H.
MIL-STD-202, Method 103,
Condition B.
Subject mated connectors to 5
cycles between -55
for 30 minutes each duration at
temperature extremes.
MIL-STD-202, Method 107,
Condition A.
Subject mated/unmated
connectors to 5% salt
concentration for 48 hours.
MIL-STD-202, Method 101,
Condition B.
o
C for 48 hours.
2
Procedures
halfsine shock
o
o
C and 85
REV
C for 96
B
o
C
o
C
LOC
ES

Related parts for 179610-1