104479-3 TE Connectivity, 104479-3 Datasheet - Page 5

SHORT POINT CONT 15 DPLX STMPD

104479-3

Manufacturer Part Number
104479-3
Description
SHORT POINT CONT 15 DPLX STMPD
Manufacturer
TE Connectivity
Datasheets

Specifications of 104479-3

Rohs Compliant
NO
Product Type
Contact
Termination Method To Wire/cable
Crimp
Wire Insulation Diameter (mm [in])
0.64 – 1.52 [0.025 – 0.060]
Connector Series
Short Point
With Insulation Support
Yes
Applied Pressure
Standard
Contact - Rated Current (a)
3
Voltage Rating (vac)
300
Termination Resistance (m?)
12
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
750
Crimp Area Plating
Tin-Lead over Nickel
Wire Range (mm [awg])
0.20-0.60² [24-20]
Contact Type
Socket
Contact Plating, Mating Area, Material
Gold (15)
Contact Base Material
Copper Alloy C7025
Rohs/elv Compliance
Not ELV/RoHS compliant
Lead Free Solder Processes
Not relevant for lead free process
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Applies To
Wire/Cable
Packaging Method
Strip
4.
4.1.
4.2.
4.3.
4.4.
Rev A
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that product meets requirements of Figure 1. Failures attributed to
equipment, test setup or operator deficiencies shall not disqualify product. When product failure occurs,
corrective action shall be taken and samples resubmitted for qualification. Testing to confirm corrective
action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan will specify sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with applicable product drawing and
this specification.
Sample Selection
Samples shall be prepared in accordance with applicable Instruction Sheets and shall be selected
at random from current production. All test groups shall each consist of a minimum of 5 connectors
containing at least 30 contacts total with receptacles crimped to wire and an equal amount of posts
of identical plating type and thickness to mate with receptacles. Test group 1 shall consist of
minimum and maximum position size connectors available. All contacts shall be crimped to
appropriate size tin plated stranded copper test conductors in accordance with Application
Specification 114-25038.
Test Sequence
Qualification inspection shall be verified by testing samples as specified in Figure 2.
108-1472
5 of 6

Related parts for 104479-3