CP82C54Z Intersil, CP82C54Z Datasheet - Page 6

IC TIMER PROG CMOS 8MHZ 24-PDIP

CP82C54Z

Manufacturer Part Number
CP82C54Z
Description
IC TIMER PROG CMOS 8MHZ 24-PDIP
Manufacturer
Intersil
Type
Programmable Timerr
Datasheet

Specifications of CP82C54Z

Frequency
8MHz
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
10mA
Operating Temperature
0°C ~ 70°C
Package / Case
24-DIP (0.600", 15.24mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Count
-
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CP82C54Z
Manufacturer:
Intersil
Quantity:
17 383
Part Number:
CP82C54Z
Manufacturer:
RENESAS
Quantity:
5 510
Part Number:
CP82C54Z
Manufacturer:
INTERS
Quantity:
1 549
Part Number:
CP82C54Z
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
CP82C54Z
0
Company:
Part Number:
CP82C54Z
Quantity:
66
Functional Description
General
The 82C54 is a programmable interval timer/counter
designed for use with microcomputer systems. It is a general
purpose, multi-timing element that can be treated as an
array of I/O ports in the system software.
The 82C54 solves one of the most common problems in any
microcomputer system, the generation of accurate time
delays under software control. Instead of setting up timing
loops in software, the programmer configures the 82C54 to
match his requirements and programs one of the counters
for the desired delay. After the desired delay, the 82C54 will
interrupt the CPU. Software overhead is minimal and
variable length delays can easily be accommodated.
Some of the other computer/timer functions common to
microcomputers which can be implemented with the 82C54
are:
• Real time clock
• Event counter
• Digital one-shot
• Programmable rate generator
• Square wave generator
• Binary rate multiplier
• Complex waveform generator
• Complex motor controller
Data Bus Buffer
This three-state, bi-directional, 8-bit buffer is used to
interface the 82C54 to the system bus (see Figure 1).
D
7
FIGURE 1. DATA BUS BUFFER AND READ/WRITE LOGIC
- D
WR
RD
CS
A
A
0
0
1
8
REGISTER
CONTROL
FUNCTIONS
BUFFER
WORD
WRITE
DATA/
READ/
LOGIC
BUS
6
COUNTER
COUNTER
COUNTER
0
1
2
CLK 0
GATE 0
OUT 0
CLK 1
GATE 1
OUT 1
CLK 2
GATE 2
OUT 2
82C54
Read/Write Logic
The Read/Write Logic accepts inputs from the system bus and
generates control signals for the other functional blocks of the
82C54. A1 and A0 select one of the three counters or the
Control Word Register to be read from/written into. A “low” on
the RD input tells the 82C54 that the CPU is reading one of the
counters. A “low” on the WR input tells the 82C54 that the CPU
is writing either a Control Word or an initial count. Both RD and
WR are qualified by CS; RD and WR are ignored unless the
82C54 has been selected by holding CS low.
Control Word Register
The Control Word Register (Figure 2) is selected by the
Read/Write Logic when A1, A0 = 11. If the CPU then does a
write operation to the 82C54, the data is stored in the
Control Word Register and is interpreted as a Control Word
used to define the Counter operation.
The Control Word Register can only be written to; status
information is available with the Read-Back Command.
Counter 0, Counter 1, Counter 2
These three functional blocks are identical in operation, so
only a single Counter will be described. The internal block
diagram of a signal counter is shown in Figure 3. The
counters are fully independent. Each Counter may operate in
a different Mode.
The Control Word Register is shown in the figure; it is not
part of the Counter itself, but its contents determine how the
Counter operates.
D
7
FIGURE 2. CONTROL WORD REGISTER AND COUNTER
- D
WR
RD
CS
A
A
0
0
1
8
REGISTER
CONTROL
FUNCTIONS
BUFFER
WORD
WRITE
LOGIC
DATA/
READ/
BUS
COUNTER
COUNTER
COUNTER
0
1
2
CLK 0
GATE 0
OUT 0
CLK 1
GATE 1
OUT 1
CLK 2
GATE 2
OUT 2

Related parts for CP82C54Z