NBC12429FA ON Semiconductor, NBC12429FA Datasheet - Page 7

no-image

NBC12429FA

Manufacturer Part Number
NBC12429FA
Description
IC CLK PLL SYNC 25-400MHZ 32LQFP
Manufacturer
ON Semiconductor
Type
PLL Clock Generatorr
Datasheet

Specifications of NBC12429FA

Pll
Yes
Input
Crystal
Output
PECL
Number Of Circuits
1
Ratio - Input:output
1:1
Differential - Input:output
No/Yes
Frequency - Max
400MHz
Divider/multiplier
Yes/No
Voltage - Supply
3.135 V ~ 5.25 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
32-LQFP
Frequency-max
400MHz
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
NBC12429FAOS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NBC12429FA
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
NBC12429FAG
Manufacturer:
ON
Quantity:
26
Part Number:
NBC12429FAG
Manufacturer:
ON Semiconductor
Quantity:
500
Part Number:
NBC12429FAG
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
NBC12429FAG
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NBC12429FAR2
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
NBC12429FAR2G
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
NBC12429FAR2G
Manufacturer:
ON/安森美
Quantity:
20 000
Table 8. AC CHARACTERISTICS
(Note 6)
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
6. F
7. 10 MHz is the maximum frequency to load the feedback divide registers. S_CLOCK can be switched at higher frequencies when used
F
F
t
t
t
jitter(pd)
jitter(cyc−cyc)
LOCK
MAXI
MAXO
Symbol
as a test clock in TEST_MODE 6.
OUT
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification
limit values are applied individually under normal operating conditions and not valid simultaneously.
/F
OUT
Maximum Input Frequency
Maximum Output Frequency
Period Jitter @ 3.3 V
10000 WFMS
(See Table 13 for Typical Values)
Period Jitter @ 5.0 V
10000 WFMS
(See Table 13 for Typical Values)
Cycle−to−Cycle @ 3.3 V
1000 WFMS
(See Table 13 for Typical Values)
Cycle−to−Cycle @ 5.0 V
1000 WFMS
(See Table 13 for Typical Values)
Maximum PLL Lock Time
outputs are terminated through a 50 W resistor to V
Characteristic
(V
CC
= 3.125 V to 5.25 V; T
VCO (Internal)
Xtal Oscillator
S_CLOCK
http://onsemi.com
F
OUT
CC
A
7
= 0°C to 70°C (NBC12429), T
(Note 7)
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
25 MHz < f
25 MHz < f
25 MHz < f
100 MHz < f
100 MHz < f
100 MHz < f
− 2.0 V.
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
Condition
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 100 MHz, M = 200
< 100 MHz, M = 300
< 100 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
< 400 MHz, M = 200
< 400 MHz, M = 300
< 400 MHz, M = 400
A
= −40°C to 85°C (NBC12429A))
Min
200
10
25
Max
400
400
146
125
168
133
108
150
105
208
192
131
164
128
186
9.0
6.0
9.0
5.0
4.0
9.0
6.0
6.0
5.0
8.0
9.0
8.0
10
20
25
71
53
60
54
25
10
69
57
49
20
17
10
77
94
89
25
12
18
10
76
10
11
11
ps
ps
ps
ps
MHz
MHz
ps
ps
ps
ps
Unit
ms
RMS
RMS
RMS
RMS
PP
PP
PP
PP

Related parts for NBC12429FA