PAXI0000 Red Lion Controls, PAXI0000 Datasheet - Page 24

1/8 DIN DIGITAL INPUT PANEL METE

PAXI0000

Manufacturer Part Number
PAXI0000
Description
1/8 DIN DIGITAL INPUT PANEL METE
Manufacturer
Red Lion Controls
Series
PAXr
Type
Multimeterr
Datasheets

Specifications of PAXI0000

Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
6
Display Digits - Height
0.560" (14.22mm)
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
6
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Panel Cutout Height
1.77"
Display Font Color
Red
Panel Cutout Width
3.62"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
1/8 DIN
Digit Height
0.56
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Counter/Rate Indicator
Indicator Type
Counter/Rate Indicator
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
±99999999
Special Features
Programmable Function Keys
Temperature, Operating, Range
0 to 50 °C
Voltage, Supply
85 to 250 VAC
Counter Supply Voltage
85-250VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Backlight
-
Measuring Range
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
Q4600348
Parameters. These parameters are used to match the serial settings of the PAXI
with those of the host computer or other serial device, such as a terminal or
printer. This programming module can only be accessed if an RS232 or RS485
Serial Communications card is installed.
required for communicating with the PAXI. In order to establish serial
communications, the user must have host software that can send and receive
ASCII characters. Red Lion's SFPAX software can be used for configuring the
PAXI (See Ordering Information). For serial hardware and wiring details, refer
to section 4.5 Serial Communication Wiring.
communications plug-in cards. Discard the separate bulletin when using those
serial plug-in cards with the PAXI. Also, this section does NOT apply to the
DeviceNet, Modbus, or Profibus-DP communication cards. For details on the
operation of the Fieldbus cards, refer to the bulletin shipped with each card.
serial link. Normally, the baud rate is set to the highest value that all the serial
equipment are capable of transmitting and receiving.
other serial communications equipment on the serial link.
on the serial link. The meter ignores the parity when receiving data and sets the
parity bit for outgoing data. If no parity is selected with 7 bit word length, an
additional stop bit is used to force the frame size to 10 bits.
6.7 MODULE 7 - S
Module 7 is the programming module for the Serial Communications
This section also includes an explanation of the commands and formatting
This section replaces the bulletin shipped with the RS232 and RS485 serial
Set the baud rate to match the other serial communications equipment on the
Select either 7 or 8 bit data word lengths. Set the word length to match the
Set the parity bit to match that of the other serial communications equipment
PAXI O
BAUD RATE
PARITY BIT
DATA BIT
NLY
ERIAL
C
PARAMETER MENU
OMMUNICATIONS
24
needed and a value of zero can be used. With multiple units (RS485
applications), a unique 2 digit address number must be assigned to each meter.
parameter data and mnemonics) or
(parameter data only). This will affect all the parameters selected in the print
options. (If the meter address is 00, it will not be sent during a full
transmission.)
print request. For each parameter in the sub-menu, select
information to be sent during a print request or
information not to be sent. A print request is sometimes referred to as a block
print because more than one parameter information (meter address, parameter
data and mnemonics) can be sent to a printer or computer as a block.
Enter the serial meter (node) address. With a single unit, an address is not
Select
PARAMETER
*Setpoints are plug-in card dependent.
- Enters the sub-menu to select the meter parameters to appear during a
A CNt
b CNt
C CNt
SCFAC
CNtLd
rAtE
HILO
SPNt
for full print or Command T transmissions (meter address,
P
DESCRIPTION
Counter A
Counter B
Counter C
Rate
Max. & Min.
A B C Scale Factors
A B C Count Load
1 2 3 4 Setpoints *
ARAMETERS
ABBREVIATED PRINTING
METER UNIT ADDRESS
PRINT OPTIONS
to
FACTORY
for abbreviated print transmissions
yES
NO
NO
NO
NO
NO
NO
NO
(
MNEMONIC
CTA
CTB
CTC
RTE
MIN MAX
SFA SFB SFC
LDA LDB LDC
SP1 SP2 SP3 SP4
for that parameter
for that parameter
)