PAXLCL00 Red Lion Controls, PAXLCL00 Datasheet - Page 4

METER CURRENT LOOP 3 1/2-DIGIT

PAXLCL00

Manufacturer Part Number
PAXLCL00
Description
METER CURRENT LOOP 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Process Meter (4-20mA Loop)r
Datasheets

Specifications of PAXLCL00

Measuring Range
4-20mA Loop
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 V ~ 250 VAC
No. Of Digits / Alpha
3-1/2
Meter Function
Loop Current
Meter Range
4mA To 20mA / 10mA To 50mA
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Accuracy
±0.05% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Ammeter
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
4 to 20/10 to 50 mA
Special Features
Multi-Range Unit
Standards
cULus Listed, CE Marked
Temperature, Operating
0 to 60 °C
Time, Response
1 Second to settle for step change
Voltage, Supply
85 to 250 VAC
Weight
0.65 lbs
Character Size
0.56"
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
RLC112
Installation
unit is intended to be mounted into an enclosed panel. Prepare the panel cutout
to the dimensions shown. Remove the panel latch from the unit. Slide the panel
gasket over the rear of the unit to the back of the bezel. The unit should be
applying power. To access the switches, remove the meter base from the case by
firmly squeezing and pulling back on the side rear finger tabs. This should lower
the latch below the case slot (which is located just in front of the finger tabs). It
is recommended to release the latch on one side, then start the other side latch.
Set-Up DIP Switches
of switches are used for calibrating the meter. The values of these switches are
discussed in section 5.0 Calibrating the Meter.
selection of decimal points and backlight annunciator. Selecting “ON” position
enables the function.
WIRING OVERVIEW
back of the meter. All conductors should conform to the meter’s voltage and
current ratings. All cabling should conform to appropriate standards of good
installation, local codes and regulations. It is recommended that power supplied
to the meter (AC) be protected by a fuse or circuit breaker.
1.0 I
2.0 S
3.0 W
BEZEL
The PAX meets NEMA 4X/IP65 requirements when properly installed. The
The meter has switches, which must be checked and/or changed prior to
Two banks of DIP switches are located inside the meter. The 10 position bank
The bank of 4 switches located near the front display are used for the
Electrical connections are made via screw-clamp terminals located on the
PANEL
GASKET
SWITCH
1
2
3
4
NSTALLING THE
ETTING THE
LATCHING
SLOTS
IRING THE
Backlight Annunciator for Units Label
Decimal Point 1 (000.0)
Decimal Point 2 (00.00)
Decimal Point 3 (0.000)
installed fully assembled. Insert the unit
PANEL
FUNCTION
into the panel cutout.
PANEL
MOUNTING
SCREWS
M
S
WITCHES
ETER
PANEL
LATCH
M
LATCHING
TABS
ETER
4
so that the tabs of the panel latch engage in the slots on the case. The panel latch
should be engaged in the farthest forward slot possible. To achieve a proper seal,
tighten the latch screws evenly until the unit is snug in the panel (Torque to
approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.
Installation Environment
operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.
meter case against those shown in wiring drawings for proper wire position. Strip
the wire, leaving approximately 0.3" (7.5 mm) bare lead exposed (stranded wires
should be tinned with solder). Insert the lead under the correct screw-clamp
terminal and tighten until the wire is secure. (Pull wire to verify tightness.)
While holding the unit in place, push the panel latch over the rear of the unit
The unit should be installed in a location that does not exceed the maximum
The bezel should be cleaned only with a soft cloth and neutral soap product.
When wiring the meter, compare the numbers embossed on the back of the
REAR TERMINALS
Main
Circuit
Board
FRONT DISPLAY
3.62
ON
4
3
2
1
(92
PANEL CUT-OUT
+.03
+.8
D.P./ BACKLIGHT
-.00
-.0
)
OFFSET
10
1
2
3
4
5
6
7
8
9
ON
OFFSET
SPAN
1.77
SPAN
(45
+.02
+.5
-.00
-.0
)